Optimizing energy efficiency and legionella control in hot water circulation systems: laboratory validation and field assessment in Swedish multifamily buildings

Hot water circulation (HWC) systems in multifamily buildings face a fundamental trade-off: maintaining temperatures sufficient to suppress Legionella pneumophila (≥50 °C) while minimizing the 2.5–4.3 TWh annual energy loss these systems represent in Sweden alone. This study employed a novel dual approach combining controlled laboratory experiments with real-world validation to address this challenge. We constructed a full-scale test rig simulating a 20-apartment building to quantify thermal losses and microbial dynamics under varying flow rates and temperatures. This was complemented by a field validation encompassing 56 water samples from 31 multifamily buildings. The results demonstrate that when optimizing the system to maintain a regulatory required return temperature of 50 °C, thermal heat losses were nearly identical between low-flow (0.2 m/s) and high-flow (0.5 m/s) operation. The decisive factor was pump energy, where high-flow operation required 3.4 times more power than low-flow operation (108 W vs. 32 W). This resulted in a total annual energy saving of approximately 12% for the low-flow strategy, entirely attributable to reduced electricity consumption for the pump. Periodic thermal shocks at 60–65 °C effectively reduced L. pneumophila concentrations, indicating that continuous high-temperature operation is not required for microbial control. Field sampling revealed that 23% of samples tested positive for legionella, with problematic cases strongly linked to design flaws like towel warmers connected to the HWC loop. These findings indicate that a risk-based strategy combining low-flow circulation (0.2 m/s), a baseline return temperature of 50 °C, and periodic thermal shocks can significantly reduce system energy consumption while maintaining legionella safety.

Authors

Publication Details

Journal
Energy Nexus
Published
2025-12-09
DOI
https://doi.org/10.1016/j.nexus.2025.100613
Primary Topic
Legionella and Acanthamoeba research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing energy efficiency and legionella control in hot water circulation systems: laboratory validation and field assessment in Swedish multifamily buildings

Jörgen Wallin, Jesper Knutsson
Energy Nexus
Legionella and Acanthamoeba research
article

Optimizing energy efficiency and legionella control in hot water circulation systems: laboratory validation and field assessment in Swedish multifamily buildings

Jörgen Wallin, Jesper Knutsson
article en

Abstract

Hot water circulation (HWC) systems in multifamily buildings face a fundamental trade-off: maintaining temperatures sufficient to suppress Legionella pneumophila (≥50 °C) while minimizing the 2.5–4.3 TWh annual energy loss these systems represent in Sweden alone. This study employed a novel dual approach combining controlled laboratory experiments with real-world validation to address this challenge. We constructed a full-scale test rig simulating a 20-apartment building to quantify thermal losses and microbial dynamics under varying flow rates and temperatures. This was complemented by a field validation encompassing 56 water samples from 31 multifamily buildings. The results demonstrate that when optimizing the system to maintain a regulatory required return temperature of 50 °C, thermal heat losses were nearly identical between low-flow (0.2 m/s) and high-flow (0.5 m/s) operation. The decisive factor was pump energy, where high-flow operation required 3.4 times more power than low-flow operation (108 W vs. 32 W). This resulted in a total annual energy saving of approximately 12% for the low-flow strategy, entirely attributable to reduced electricity consumption for the pump. Periodic thermal shocks at 60–65 °C effectively reduced L. pneumophila concentrations, indicating that continuous high-temperature operation is not required for microbial control. Field sampling revealed that 23% of samples tested positive for legionella, with problematic cases strongly linked to design flaws like towel warmers connected to the HWC loop. These findings indicate that a risk-based strategy combining low-flow circulation (0.2 m/s), a baseline return temperature of 50 °C, and periodic thermal shocks can significantly reduce system energy consumption while maintaining legionella safety.

Energy NexusVol. 21
Openalex Percentile: Top 66%
Legionella and Acanthamoeba research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.