Structural analysis of cone photoreceptors in AO-OCT enables S-cone identification by a support vector machine classifier

Adaptive optics optical coherence tomography (AO-OCT) enables high-resolution, 3-dimensional imaging of cone photoreceptors in the living human retina. Histological studies have shown that short-wavelength-sensitive (S) cones are structurally distinct from medium- (M) and long-wavelength-sensitive (L) cones. However, current <i>in vivo</i> methods for classifying cones-such as retinal densitometry and optoretinography-are technically demanding because they require measuring cone function. Quantifying structural differences with AO-OCT may provide a simpler and faster alternative and offer new biomarkers for understanding how disease differentially affects photoreceptor subtypes. Here, we present a quantitative method that applies a support vector machine (SVM) classifier to structural measurements of AO-OCT volumes to identify individual S cones. We measured six structural parameters related to the inner and outer segments of each cone. Among 13,836 cones analyzed across six subjects, we found S cones exhibited significantly longer inner segments, shorter outer segments, and wider diameters at the inner/outer segment junction than M and L cones. Although M and L cones are widely regarded as morphologically indistinguishable, we also found that L cones, on average, had longer outer segments than M cones. These structural differences were consistent across five of the six subjects at a single retinal eccentricity of 3.7° and across eccentricities from 2° to 12° temporal in one subject. Our SVM model used these features to achieve high classification accuracy for S cones. Validation of classification performance against optoretinography on the same eyes yielded F1 scores ranging from 0.78 to 0.93 in five of the six subjects.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2025-12-09
DOI
https://doi.org/10.1364/boe.581923
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structural analysis of cone photoreceptors in AO-OCT enables S-cone identification by a support vector machine classifier

Donald T. Miller, Marcel T. Bernucci, Qiuzhi Ji, Davin J. Miller et al.
Biomedical Optics Express
Optical Coherence Tomography Applications
article

Structural analysis of cone photoreceptors in AO-OCT enables S-cone identification by a support vector machine classifier

Donald T. Miller, Marcel T. Bernucci, Qiuzhi Ji, Davin J. Miller, Yan Liu, James A. Crowell
article en

Abstract

Adaptive optics optical coherence tomography (AO-OCT) enables high-resolution, 3-dimensional imaging of cone photoreceptors in the living human retina. Histological studies have shown that short-wavelength-sensitive (S) cones are structurally distinct from medium- (M) and long-wavelength-sensitive (L) cones. However, current <i>in vivo</i> methods for classifying cones-such as retinal densitometry and optoretinography-are technically demanding because they require measuring cone function. Quantifying structural differences with AO-OCT may provide a simpler and faster alternative and offer new biomarkers for understanding how disease differentially affects photoreceptor subtypes. Here, we present a quantitative method that applies a support vector machine (SVM) classifier to structural measurements of AO-OCT volumes to identify individual S cones. We measured six structural parameters related to the inner and outer segments of each cone. Among 13,836 cones analyzed across six subjects, we found S cones exhibited significantly longer inner segments, shorter outer segments, and wider diameters at the inner/outer segment junction than M and L cones. Although M and L cones are widely regarded as morphologically indistinguishable, we also found that L cones, on average, had longer outer segments than M cones. These structural differences were consistent across five of the six subjects at a single retinal eccentricity of 3.7° and across eccentricities from 2° to 12° temporal in one subject. Our SVM model used these features to achieve high classification accuracy for S cones. Validation of classification performance against optoretinography on the same eyes yielded F1 scores ranging from 0.78 to 0.93 in five of the six subjects.

Biomedical Optics ExpressVol. 17(1)
Emory Johns Creek Hospital (US), Indiana University Bloomington (US), John Deere (Germany) (DE), Indiana University (US)
Openalex Percentile: Top 62%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.