Repeatability of Rapid Human Cardiac Phosphorus <scp>MRSI</scp> ( <scp> <sup>31</sup> P </scp> ‐ <scp>MRSI</scp> ) Using Concentric Ring Trajectory Readouts at 7 T

We established the repeatability of CRT-MRSI-based PCr/ATP values and showed higher SNR and lower CoR for CRT-SLAM. Our findings allow shorter <sup>31</sup>P MRS acquisition times and the use of more advanced energetics-probing techniques in clinical studies.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2025-12-08
DOI
https://doi.org/10.1002/mrm.70220
Citations
1
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Repeatability of Rapid Human Cardiac Phosphorus MRSI ( 31 P ‐ MRSI ) Using Concentric Ring Trajectory Readouts at 7 T

Christopher T. Rodgers, Andrew Tyler, Jabrane Karkouri, Wolfgang Bogner et al.
1 citations
Magnetic Resonance in Medicine
Advanced MRI Techniques and Applications
1.36
article

Repeatability of Rapid Human Cardiac Phosphorus MRSI ( 31 P ‐ MRSI ) Using Concentric Ring Trajectory Readouts at 7 T

Christopher T. Rodgers, Andrew Tyler, Jabrane Karkouri, Wolfgang Bogner, Jack J. Miller, William T. Clarke, Ferenc E. Mózes, Fabian Niess, Ladislav Valkovič
article en
1 citations

Abstract

We established the repeatability of CRT-MRSI-based PCr/ATP values and showed higher SNR and lower CoR for CRT-SLAM. Our findings allow shorter <sup>31</sup>P MRS acquisition times and the use of more advanced energetics-probing techniques in clinical studies.

Magnetic Resonance in MedicineVol. 95(5)
Aarhus University (DK), Slovak Academy of Sciences (SK), University of Cambridge (GB), Manchester Academic Health Science Centre (GB), John Radcliffe Hospital (GB), University of Oxford (GB), Institute of Measurement Science of the Slovak Academy of Sciences (SK), Wellcome Centre for Integrative Neuroimaging (GB), Oxford BioMedica (United Kingdom) (GB), Medical University of Vienna (AT)
Wellcome Trust, National Institute for Health and Care Research, Department of Health and Social Care, Austrian Science Fund, Novo Nordisk, Agentúra na Podporu Výskumu a Vývoja, Vedecká Grantová Agentúra MŠVVaŠ SR a SAV, Novo Nordisk Fonden, Directorate for Biological Sciences, Biotechnology and Biological Sciences Research Council, NIHR Oxford Biomedical Research Centre, NIHR Cambridge Biomedical Research Centre
Openalex Percentile: Top 14%
Advanced MRI Techniques and Applications
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.