Transcatheter Closure of an Ascending Aortic Pseudoaneurysm Guided by Intracardiac Echocardiography
A 60-year-old man with a history of multiple cardiac surgeries presented with exertional dyspnea. CT revealed a 20 × 10 mm ascending aortic pseudoaneurysm with a neck diameter of 7 mm, located near the suture line of a previous aortic root replacement, compressing a saphenous vein graft (SVG). Given the high risk of reoperation, percutaneous catheter closure with a 9/12 mm Amplatzer Vascular Plug II (AVP II) was performed alongside drug-eluting stent (4.0 × 18 mm) implantation to address SVG stenosis. Intraoperative intracardiac echocardiography (ICE) was essential for guiding AVP II deployment and ensuring accurate placement. This case highlights the effectiveness and safety of ICE-guided percutaneous interventions in managing complex aortic pathologies in high-risk patients. Successful closure of the pseudoaneurysm and resolution of the SVG compression demonstrated the feasibility of this minimally invasive approach in patients with complex surgical histories.
Authors
- Hiromasa Hayama (ORCID: https://orcid.org/0000-0001-6702-7150)
- Hidehiko Hara (ORCID: https://orcid.org/0000-0003-2501-4663)
- Y Yazaki (ORCID: https://orcid.org/0000-0003-4976-1022)
- Kenji Makino (ORCID: https://orcid.org/0000-0002-9850-8931)
- Go Hashimoto (ORCID: https://orcid.org/0000-0001-5067-2786)
- Manabu Sato
- Yae Matsuo
Institutions
- Toho University (JP)
- Toho University Ohashi Medical Center (JP)
- Kanto Central Hospital (JP)
Publication Details
- Journal
- Cureus
- Published
- 2025-12-08
- DOI
- https://doi.org/10.7759/cureus.98755
- Primary Topic
- Aortic Disease and Treatment Approaches
- Type
- article
- Field-Weighted Citation Impact
- 0.00