Optimization Process of PCL/TPU@MWCNTs Fiber Composites for Flexible Piezoresistive Sensors and Application in Hand Movements Perception

This study outlines the optimization process for a polycaprolactone (PCL)/polyurethane (TPU)@multiwalled carbon nanotubes (MWCNTs) fiber composite, designed explicitly for flexible piezoresistive sensors. The PCL/TPU fiber membrane prepared by electrospinning technology was used as the substrate. Functionalized MWCNTs, serving as exogenous conductive particles, were deposited on the membrane via vacuum filtration, thereby preparing the PCL/TPU@MWCNTs fiber composite. This study investigated the morphological characteristics, hydrophobicity, mechanical properties, and conductivity of the PCL/TPU@MWCNTs fiber composite. The aim was to determine suitable preparation parameters for flexible pressure sensors ideal for outdoor and medical applications. The test results indicated that the membrane spun at 28 kV and a spinning distance of 20 cm exhibited optimal mechanical properties. With a filtration volume of 7.5 mL, the MWCNTs in the membrane were uniformly distributed, with a thickness of 0.05 ± 0.01 mm, a water contact angle of 131°, a tensile strength of 14 MPa, an elongation at break of 32.4%, and a conductivity of 1.74 × 10<sup>-4</sup> S/m. The prepared sensor exhibited sensitivities of 1.86 kPa<sup>-1</sup> over 0-34 and 1.14 kPa<sup>-1</sup> over 35-75 kPa, with rise and fall response times of 9.41 and 10.89 ms, respectively. The sensor measured an average normalized peak output of 10.7108 (Δ<i>R</i>/<i>R</i> <sub>0</sub>%) for the index finger across 200 bending/straightening cycles, with a standard deviation of 0.02249. Furthermore, in tests involving unscrewing a bottle cap with two fingers, load pressure pulse patterns were successfully recognized over the 0-150 Hz frequency range. This preparation method demonstrates advantages in action recognition at high frequencies and aids precise control and optimization of finger movements.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2025-12-08
DOI
https://doi.org/10.1021/acsomega.5c08191
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization Process of PCL/TPU@MWCNTs Fiber Composites for Flexible Piezoresistive Sensors and Application in Hand Movements Perception

Zhenjiang Liu, Ping Zhu, Lan Qian
ACS Omega
Advanced Sensor and Energy Harvesting Materials
article

Optimization Process of PCL/TPU@MWCNTs Fiber Composites for Flexible Piezoresistive Sensors and Application in Hand Movements Perception

Zhenjiang Liu, Ping Zhu, Lan Qian
article en

Abstract

This study outlines the optimization process for a polycaprolactone (PCL)/polyurethane (TPU)@multiwalled carbon nanotubes (MWCNTs) fiber composite, designed explicitly for flexible piezoresistive sensors. The PCL/TPU fiber membrane prepared by electrospinning technology was used as the substrate. Functionalized MWCNTs, serving as exogenous conductive particles, were deposited on the membrane via vacuum filtration, thereby preparing the PCL/TPU@MWCNTs fiber composite. This study investigated the morphological characteristics, hydrophobicity, mechanical properties, and conductivity of the PCL/TPU@MWCNTs fiber composite. The aim was to determine suitable preparation parameters for flexible pressure sensors ideal for outdoor and medical applications. The test results indicated that the membrane spun at 28 kV and a spinning distance of 20 cm exhibited optimal mechanical properties. With a filtration volume of 7.5 mL, the MWCNTs in the membrane were uniformly distributed, with a thickness of 0.05 ± 0.01 mm, a water contact angle of 131°, a tensile strength of 14 MPa, an elongation at break of 32.4%, and a conductivity of 1.74 × 10<sup>-4</sup> S/m. The prepared sensor exhibited sensitivities of 1.86 kPa<sup>-1</sup> over 0-34 and 1.14 kPa<sup>-1</sup> over 35-75 kPa, with rise and fall response times of 9.41 and 10.89 ms, respectively. The sensor measured an average normalized peak output of 10.7108 (Δ<i>R</i>/<i>R</i> <sub>0</sub>%) for the index finger across 200 bending/straightening cycles, with a standard deviation of 0.02249. Furthermore, in tests involving unscrewing a bottle cap with two fingers, load pressure pulse patterns were successfully recognized over the 0-150 Hz frequency range. This preparation method demonstrates advantages in action recognition at high frequencies and aids precise control and optimization of finger movements.

ACS OmegaVol. 10(50)
North University of China (CN)
Openalex Percentile: Top 62%
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.