Cardiac 3D Motion Reconstruction Using Dual-Camera Defocused Speckle Imaging With Multi-Scale Amplification

Cardiovascular diseases are one of the leading causes of death worldwide. Accurately capturing and analyzing the multidimensional dynamics of cardiac motion is crucial for early diagnosis and rehabilitation assessment. This study introduces a novel concept for non-contact cardiac linear vibration (SCG) and rotational components (GCGx and GCGy) decoupling and reconstruction by integrating speckle motion signals captured from two cameras with different defocus levels. The intention is to overcome the motion coupling issues inherent in single-camera imaging and improve the accuracy in characterizing the cardiac complex 3D mechanical behavior. Using a sternum-mounted inertial sensor as the reference, experiments were conducted on 42 subjects in laboratory and intensive care unit settings. The results show that the reconstructed cardiac 3D motion signals exhibit greater waveform similarity to the reference signal than the raw speckle motion signal from a single camera, with similarity indices above 87.471%. In addition, with an 8 ms tolerance error, the localization accuracy of 6 key biomarkers (aortic valve opening/closing (AO/AC), mitral valve opening/closing (MO/MC), the biomarkers corresponding to the AO event in GCGy and the MC event in GCGx) are 73.080%, 99.998%, 85.587%, 86.617%, 99.683% and 77.301%, respectively. These results also outperform those obtained from the raw speckle motion signal. These findings validate the rationale and effectiveness of using dual-camera imaging with different defocus levels to reconstruct SCG, GCGx, and GCGy, offering a promising approach for accurately capturing complex cardiac 3D motion and improving cardiac function assessment.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Biomedical and Health Informatics
Published
2025-12-01
DOI
https://doi.org/10.1109/jbhi.2025.3617825
Citations
1
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
1.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cardiac 3D Motion Reconstruction Using Dual-Camera Defocused Speckle Imaging With Multi-Scale Amplification

Wenjin Wang, Yifei Da, Caifeng Shan, Haimiao Mo et al.
1 citations
IEEE Journal of Biomedical and Health Informatics
Ultrasound Imaging and Elastography
1.36
article

Cardiac 3D Motion Reconstruction Using Dual-Camera Defocused Speckle Imaging With Multi-Scale Amplification

Wenjin Wang, Yifei Da, Caifeng Shan, Haimiao Mo, Guowei Wang, Lin Liu, Yingen Zhu
article en
1 citations

Abstract

Cardiovascular diseases are one of the leading causes of death worldwide. Accurately capturing and analyzing the multidimensional dynamics of cardiac motion is crucial for early diagnosis and rehabilitation assessment. This study introduces a novel concept for non-contact cardiac linear vibration (SCG) and rotational components (GCGx and GCGy) decoupling and reconstruction by integrating speckle motion signals captured from two cameras with different defocus levels. The intention is to overcome the motion coupling issues inherent in single-camera imaging and improve the accuracy in characterizing the cardiac complex 3D mechanical behavior. Using a sternum-mounted inertial sensor as the reference, experiments were conducted on 42 subjects in laboratory and intensive care unit settings. The results show that the reconstructed cardiac 3D motion signals exhibit greater waveform similarity to the reference signal than the raw speckle motion signal from a single camera, with similarity indices above 87.471%. In addition, with an 8 ms tolerance error, the localization accuracy of 6 key biomarkers (aortic valve opening/closing (AO/AC), mitral valve opening/closing (MO/MC), the biomarkers corresponding to the AO event in GCGy and the MC event in GCGx) are 73.080%, 99.998%, 85.587%, 86.617%, 99.683% and 77.301%, respectively. These results also outperform those obtained from the raw speckle motion signal. These findings validate the rationale and effectiveness of using dual-camera imaging with different defocus levels to reconstruct SCG, GCGx, and GCGy, offering a promising approach for accurately capturing complex cardiac 3D motion and improving cardiac function assessment.

IEEE Journal of Biomedical and Health InformaticsVol. 29(12)
Southern University of Science and Technology (CN), Suzhou University of Science and Technology (CN), Longgang Central Hospital (CN), Shenzhen Third People’s Hospital (CN), Shandong University of Science and Technology (CN)
Openalex Percentile: Top 14%
Ultrasound Imaging and Elastography
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.