Real-World Validation of the VIVEX Formula for Vitreous Volume Estimation in Vitreoretinal Surgery: A First Clinical Case Series

The VIVEX formula demonstrates high correlation and clinically useful accuracy for individualized vitreous volume estimation across common surgical contexts. It seems that the largest error and a positive bias occur during silicone oil removal, warranting caution in oil-filled eyes. In such cases, measurement artifacts due to altered optical pathways in silicone-oil-filled eyes and the possible presence of residual oil remnants after removal may contribute to minor discrepancies between calculated and true intraoperative volumes, indicating a need for further evaluation. Overall, VIVEX may assist preoperative planning and realistic volume targeting in routine practice. As this is the first clinical case series evaluating the VIVEX formula in real surgical settings, larger prospective multicenter studies are needed to confirm and expand the findings.

Authors

Institutions

Publication Details

Journal
Ophthalmology and Therapy
Published
2025-12-08
DOI
https://doi.org/10.1007/s40123-025-01291-z
Primary Topic
Retinal and Macular Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-World Validation of the VIVEX Formula for Vitreous Volume Estimation in Vitreoretinal Surgery: A First Clinical Case Series

Boris Malyugin, Eva-Maria Borkenstein, Andreas F. Borkenstein, А. И. Колесник
Ophthalmology and Therapy
Retinal and Macular Surgery
article

Real-World Validation of the VIVEX Formula for Vitreous Volume Estimation in Vitreoretinal Surgery: A First Clinical Case Series

Boris Malyugin, Eva-Maria Borkenstein, Andreas F. Borkenstein, А. И. Колесник
article en

Abstract

The VIVEX formula demonstrates high correlation and clinically useful accuracy for individualized vitreous volume estimation across common surgical contexts. It seems that the largest error and a positive bias occur during silicone oil removal, warranting caution in oil-filled eyes. In such cases, measurement artifacts due to altered optical pathways in silicone-oil-filled eyes and the possible presence of residual oil remnants after removal may contribute to minor discrepancies between calculated and true intraoperative volumes, indicating a need for further evaluation. Overall, VIVEX may assist preoperative planning and realistic volume targeting in routine practice. As this is the first clinical case series evaluating the VIVEX formula in real surgical settings, larger prospective multicenter studies are needed to confirm and expand the findings.

Ophthalmology and TherapyVol. 15(1)
Doheny Eye Institute (US), Southern California Eye Institute (US), Barmherzige Schwestern vom heiligen Kreuz (AT), Intersectoral Research and Technology Complex Eye Microsurgery (RU)
Openalex Percentile: Top 46%
Retinal and Macular Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.