Evaluating Trends in Radiation Dose During Fluoroscopic Lumbar Puncture

Introduction Minimizing patient radiation exposure when performing procedures under fluoroscopy is important for ensuring patient safety. Our primary objective in this quality improvement study was to assess trends in fluoroscopy time during image-guided lumbar punctures. In addition, we assessed the demographic and clinical factors that influenced fluoroscopy time during these procedures. Methods Data on patient body mass index (BMI), patient age, and sedation method were obtained. In addition, information on the performing healthcare provider and date of procedure were obtained in order to derive the number of lumbar punctures previously performed by individual providers at the time of the procedure. Data were analyzed using ANOVA and a p<.05 was considered significant. Results A total of 370 fluoroscopy-guided lumbar punctures performed by resident physicians, attending physicians, and physician assistants were reviewed. A statistically significant difference in mean fluoroscopy time was identified in patients of differing ages with older age being associated with higher fluoroscopy times (p<0.01). No significant difference existed regarding patient BMI (p=0.16) or method of sedation (p=0.84) when compared to mean fluoroscopy time. A statistically significant decrease in fluoroscopy time was observed as more lumbar punctures were performed by clinicians (p=0.02). Conclusions Significant increases in mean fluoroscopy times were observed in older patients, which may be secondary to degenerative changes of the spine making access to the thecal sac more difficult. No significant difference in mean fluoroscopy time was identified in regards to patient BMI or method of sedation. Using a formula derived from our data describing decreases in fluoroscopy time based on the number of procedures performed, it may be possible to predict how many lumbar punctures need to be performed by new trainees in order to reach certain levels of proficiency.

Authors

Institutions

Publication Details

Journal
Michigan medical education and health bulletin.
Published
2025-12-08
DOI
https://doi.org/10.69735/001c.146703
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating Trends in Radiation Dose During Fluoroscopic Lumbar Puncture

Grace D Brannan, Samuel J. Wisniewski, Jacob Babb, Eric Rinker et al.
Michigan medical education and health bulletin.
Radiation Dose and Imaging
article

Evaluating Trends in Radiation Dose During Fluoroscopic Lumbar Puncture

Grace D Brannan, Samuel J. Wisniewski, Jacob Babb, Eric Rinker, Alex Kaechele
article en

Abstract

Introduction Minimizing patient radiation exposure when performing procedures under fluoroscopy is important for ensuring patient safety. Our primary objective in this quality improvement study was to assess trends in fluoroscopy time during image-guided lumbar punctures. In addition, we assessed the demographic and clinical factors that influenced fluoroscopy time during these procedures. Methods Data on patient body mass index (BMI), patient age, and sedation method were obtained. In addition, information on the performing healthcare provider and date of procedure were obtained in order to derive the number of lumbar punctures previously performed by individual providers at the time of the procedure. Data were analyzed using ANOVA and a p<.05 was considered significant. Results A total of 370 fluoroscopy-guided lumbar punctures performed by resident physicians, attending physicians, and physician assistants were reviewed. A statistically significant difference in mean fluoroscopy time was identified in patients of differing ages with older age being associated with higher fluoroscopy times (p<0.01). No significant difference existed regarding patient BMI (p=0.16) or method of sedation (p=0.84) when compared to mean fluoroscopy time. A statistically significant decrease in fluoroscopy time was observed as more lumbar punctures were performed by clinicians (p=0.02). Conclusions Significant increases in mean fluoroscopy times were observed in older patients, which may be secondary to degenerative changes of the spine making access to the thecal sac more difficult. No significant difference in mean fluoroscopy time was identified in regards to patient BMI or method of sedation. Using a formula derived from our data describing decreases in fluoroscopy time based on the number of procedures performed, it may be possible to predict how many lumbar punctures need to be performed by new trainees in order to reach certain levels of proficiency.

Michigan medical education and health bulletin.Vol. 3(3)
Genesys (United States) (US), Providence Hospital (US), Henry Ford Hospital (US), Statistical Research (United States) (US), Michigan State University (US)
Openalex Percentile: Top 46%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.