Hydrolytic degradation behaviour of electrospun poly( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" altimg="si2.svg" display="inline" id="d1e722"> <mml:mi>ɛ</mml:mi> </mml:math> -caprolactone) filaments for biological tissue repair

Electrospun polymeric fibres are promising materials for biomedical applications, owing to their biocompatibility, biodegradability, and ability to be assembled into a non-woven fibrous mesh. In particular, continuous filaments can be produced and subsequently assembled into multi-filament braided structures for ligament and tendon tissue repair. In these applications, characterising the evolution of the mechanical properties of the filament as it degrades is of primary importance. The role of applied mechanical loads during the degradation process also needs to be understood. In this study, we characterised the hydrolytic degradation behaviour of pre-stretched electrospun filaments made of poly(ɛ- caprolactone) (PCL) in buffer saline solution at 45 °C for up to 5 weeks, considering both non-loaded and loaded conditions. We show that PCL filaments degrade significantly over this relatively short time period, with non-loaded specimens showing a 21 % reduction in molecular weight after 5 weeks of exposure. Tensile loads applied during degradation further accelerate the degradation rate, with filaments subjected to a 25 g load showing a 33 % reduction in molecular weight over the same time period. Applied loads also impact the mechanical properties of the degraded specimens, causing an increase in elastic modulus and strength but a sharp decrease in elongation at break with exposure time. Our findings have implications for the design of PCL electrospun constructs in load bearing biomedical applications.

Authors

Institutions

Publication Details

Journal
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Published
2025-12-08
DOI
https://doi.org/10.1016/j.jmbbm.2025.107308
Primary Topic
Electrospun Nanofibers in Biomedical Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hydrolytic degradation behaviour of electrospun poly( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" altimg="si2.svg" display="inline" id="d1e722"> <mml:mi>ɛ</mml:mi> </mml:math> -caprolactone) filaments for biological tissue repair

H. Chen, Pierre‐Alexis Mouthuy, Kaili Chen, Laurence Brassart et al.
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Electrospun Nanofibers in Biomedical Applications
article

Hydrolytic degradation behaviour of electrospun poly( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" altimg="si2.svg" display="inline" id="d1e722"> <mml:mi>ɛ</mml:mi> </mml:math> -caprolactone) filaments for biological tissue repair

H. Chen, Pierre‐Alexis Mouthuy, Kaili Chen, Laurence Brassart, Thales Zanetti Ferreira
article en

Abstract

Electrospun polymeric fibres are promising materials for biomedical applications, owing to their biocompatibility, biodegradability, and ability to be assembled into a non-woven fibrous mesh. In particular, continuous filaments can be produced and subsequently assembled into multi-filament braided structures for ligament and tendon tissue repair. In these applications, characterising the evolution of the mechanical properties of the filament as it degrades is of primary importance. The role of applied mechanical loads during the degradation process also needs to be understood. In this study, we characterised the hydrolytic degradation behaviour of pre-stretched electrospun filaments made of poly(ɛ- caprolactone) (PCL) in buffer saline solution at 45 °C for up to 5 weeks, considering both non-loaded and loaded conditions. We show that PCL filaments degrade significantly over this relatively short time period, with non-loaded specimens showing a 21 % reduction in molecular weight after 5 weeks of exposure. Tensile loads applied during degradation further accelerate the degradation rate, with filaments subjected to a 25 g load showing a 33 % reduction in molecular weight over the same time period. Applied loads also impact the mechanical properties of the degraded specimens, causing an increase in elastic modulus and strength but a sharp decrease in elongation at break with exposure time. Our findings have implications for the design of PCL electrospun constructs in load bearing biomedical applications.

Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materialsVol. 175
Nuffield Orthopaedic Centre (GB), University of Oxford (GB), NIHR Oxford Musculoskeletal Biomedical Research Centre (GB), Science Oxford (GB)
Openalex Percentile: Top 73%
Electrospun Nanofibers in Biomedical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.