Development of an Algorithm to Assist in the Diagnosis of Combined Retinal Vein Occlusion and Glaucoma

<b>Objectives:</b> To develop an algorithm to assist in the diagnosis of glaucoma with concomitant retinal vein occlusion (RVO) and to compare its diagnostic accuracy with that of ophthalmology residents and specialists. <b>Methods:</b> Fundus photographs of eyes with RVO and those with both RVO and glaucoma were obtained from patients who visited the University of Yamanashi Hospital. All images were preprocessed through normalization and resized to 512 × 512 pixels to ensure uniformity before model training. The diagnostic accuracy of two algorithms-the Comprehensive Fundus Disease Diagnostic Artificial Intelligence Algorithm (CD-AI) and the Glaucoma Concomitant RVO Artificial Intelligence Algorithm (RVO-GLA AI)-was evaluated. CD-AI is a clinical decision support algorithm originally developed to detect eleven common fundus diseases, including glaucoma and RVO. RVO-GLA AI is a fine-tuned version of CD-AI that is specifically adapted to detect glaucoma with or without RVO. Fine-tuning was performed using 1234 images of glaucoma, 1233 images of nonglaucomatous conditions, including RVO, and 15 images of cases with both glaucoma and RVO. The number of comorbid cases was determined empirically by gradually adding glaucomatous eyes with concomitant RVO to the training set, and 15 images provided the best balance between sensitivity and specificity. Because the available number of such cases was limited, this small sample size may have influenced the stability of the performance estimates. For the final evaluation, both algorithms and all ophthalmologists assessed the same independent test dataset comprising 66 fundus images (16 eyes with glaucoma and RVO and 50 eyes with RVO alone). The diagnostic performance of both algorithms was compared with that of three first-year ophthalmology residents and three board-certified ophthalmologists. <b>Results:</b> CD-AI demonstrated high diagnostic accuracy (92.5%) in eyes with glaucoma alone. However, its sensitivity and specificity decreased to 0.375 and 1.0, respectively, in patients with concomitant RVO. In contrast, the RVO-GLA AI achieved an area under the curve (AUC) of 0.875, with a sensitivity of 0.87 and a specificity of 0.71. Across all the ophthalmologists, the average sensitivity was 0.63, and the specificity was 0.87. Specialists achieved a sensitivity of 0.80 and a specificity of 0.89, while residents had a sensitivity of 0.46 and a specificity of 0.85. <b>Conclusions:</b> An AI-based clinical decision support system specifically designed for glaucoma detection significantly improved diagnostic performance in eyes with combined RVO and glaucoma, achieving an accuracy comparable to that of ophthalmologists, even with a limited number of training cases.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-12-02
DOI
https://doi.org/10.3390/jcm14238547
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of an Algorithm to Assist in the Diagnosis of Combined Retinal Vein Occlusion and Glaucoma

Kazuyoshi Kitamura, Kenji Kashiwagi, Kohei Murao, Kensaku Mori et al.
Journal of Clinical Medicine
Retinal Imaging and Analysis
article

Development of an Algorithm to Assist in the Diagnosis of Combined Retinal Vein Occlusion and Glaucoma

Kazuyoshi Kitamura, Kenji Kashiwagi, Kohei Murao, Kensaku Mori, Masaki Tanito, Takeshi Yoshitomi, Yuka Hasebe, Atsuya Miki, Hiroshi Kasai, Y Ninomiya, Kazuhiko Mori, Shiori Sato, Kazuhide Kawase, Toru Nakazawa, Junya Mizutani, Kengo Utsunomiya
article en

Abstract

<b>Objectives:</b> To develop an algorithm to assist in the diagnosis of glaucoma with concomitant retinal vein occlusion (RVO) and to compare its diagnostic accuracy with that of ophthalmology residents and specialists. <b>Methods:</b> Fundus photographs of eyes with RVO and those with both RVO and glaucoma were obtained from patients who visited the University of Yamanashi Hospital. All images were preprocessed through normalization and resized to 512 × 512 pixels to ensure uniformity before model training. The diagnostic accuracy of two algorithms-the Comprehensive Fundus Disease Diagnostic Artificial Intelligence Algorithm (CD-AI) and the Glaucoma Concomitant RVO Artificial Intelligence Algorithm (RVO-GLA AI)-was evaluated. CD-AI is a clinical decision support algorithm originally developed to detect eleven common fundus diseases, including glaucoma and RVO. RVO-GLA AI is a fine-tuned version of CD-AI that is specifically adapted to detect glaucoma with or without RVO. Fine-tuning was performed using 1234 images of glaucoma, 1233 images of nonglaucomatous conditions, including RVO, and 15 images of cases with both glaucoma and RVO. The number of comorbid cases was determined empirically by gradually adding glaucomatous eyes with concomitant RVO to the training set, and 15 images provided the best balance between sensitivity and specificity. Because the available number of such cases was limited, this small sample size may have influenced the stability of the performance estimates. For the final evaluation, both algorithms and all ophthalmologists assessed the same independent test dataset comprising 66 fundus images (16 eyes with glaucoma and RVO and 50 eyes with RVO alone). The diagnostic performance of both algorithms was compared with that of three first-year ophthalmology residents and three board-certified ophthalmologists. <b>Results:</b> CD-AI demonstrated high diagnostic accuracy (92.5%) in eyes with glaucoma alone. However, its sensitivity and specificity decreased to 0.375 and 1.0, respectively, in patients with concomitant RVO. In contrast, the RVO-GLA AI achieved an area under the curve (AUC) of 0.875, with a sensitivity of 0.87 and a specificity of 0.71. Across all the ophthalmologists, the average sensitivity was 0.63, and the specificity was 0.87. Specialists achieved a sensitivity of 0.80 and a specificity of 0.89, while residents had a sensitivity of 0.46 and a specificity of 0.85. <b>Conclusions:</b> An AI-based clinical decision support system specifically designed for glaucoma detection significantly improved diagnostic performance in eyes with combined RVO and glaucoma, achieving an accuracy comparable to that of ophthalmologists, even with a limited number of training cases.

Journal of Clinical MedicineVol. 14(23)
Aichi Medical University (JP), Shimane University (JP), National Institute of Informatics (JP), Tohoku University (JP), Fukuoka International University (JP), Kyoto Prefectural University of Medicine (JP), Minamiaoyama Eye Clinic (JP), Baptist Hospital (US), Nagoya University (JP), University of Yamanashi (JP)
Openalex Percentile: Top 46%
Retinal Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.