Haptic Visual and Superimposed Digital Imaging Analysis Improves the Interrater Reliability of J-Sign Assessment in Patients with Patellofemoral Instability: A Prospective Diagnostic Study

<b>Background:</b> J-sign assessment is increasingly important for decision-making in patients with patellar instability. However, the low interrater reliability of the J-sign evaluation has raised concerns. The aim of this study was to investigate whether haptic visual assessment or superimposed digital imaging analysis might improve interrater reliability. <b>Methods:</b> In 51 patients with ≥ 1 patellar dislocation, J-sign grading was assessed by two experienced observers via three different methods: (i) plain visual evaluation; (ii) combined haptic visual assessment, including palpation of the medial and lateral patellar facets with the thumb and index finger during active knee joint motion; and (iii) a digital photo application tool using superimposed digital imaging analysis obtained at 90° of flexion-knee joint flexion and full extension. <b>Results:</b> For the visual assessment of the J-sign, the interrater reliability was fair, with κ = 0.39 ± 0.11 [0.18-0.6]. The interrater reliability of the haptic visual assessment and the photo application reached a good level of agreement, with κ = 0.89 ± 0.05 [0.8-0.98] and κ = 0.85 ± 0.05 [0.74-0.95], respectively. <b>Conclusions:</b> Plain visual evaluation of the J-sign revealed fair interrater reliability. The haptic visual assessment of the J-sign and the digital photo application tool yielded good interrater reliability. The results indicate that haptic visual assessment of J-sign should be implemented in daily clinical practice and used to communicate findings between and among physicians and studies.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-12-02
DOI
https://doi.org/10.3390/jcm14238559
Primary Topic
Lower Extremity Biomechanics and Pathologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Haptic Visual and Superimposed Digital Imaging Analysis Improves the Interrater Reliability of J-Sign Assessment in Patients with Patellofemoral Instability: A Prospective Diagnostic Study

Paul Alfred Gruetzner, Peter Balcarek, Eric Mandelka, Sven Yves Vetter et al.
Journal of Clinical Medicine
Lower Extremity Biomechanics and Pathologies
article

Haptic Visual and Superimposed Digital Imaging Analysis Improves the Interrater Reliability of J-Sign Assessment in Patients with Patellofemoral Instability: A Prospective Diagnostic Study

Paul Alfred Gruetzner, Peter Balcarek, Eric Mandelka, Sven Yves Vetter, Felix Zimmermann, Jula Gierse
article en

Abstract

<b>Background:</b> J-sign assessment is increasingly important for decision-making in patients with patellar instability. However, the low interrater reliability of the J-sign evaluation has raised concerns. The aim of this study was to investigate whether haptic visual assessment or superimposed digital imaging analysis might improve interrater reliability. <b>Methods:</b> In 51 patients with ≥ 1 patellar dislocation, J-sign grading was assessed by two experienced observers via three different methods: (i) plain visual evaluation; (ii) combined haptic visual assessment, including palpation of the medial and lateral patellar facets with the thumb and index finger during active knee joint motion; and (iii) a digital photo application tool using superimposed digital imaging analysis obtained at 90° of flexion-knee joint flexion and full extension. <b>Results:</b> For the visual assessment of the J-sign, the interrater reliability was fair, with κ = 0.39 ± 0.11 [0.18-0.6]. The interrater reliability of the haptic visual assessment and the photo application reached a good level of agreement, with κ = 0.89 ± 0.05 [0.8-0.98] and κ = 0.85 ± 0.05 [0.74-0.95], respectively. <b>Conclusions:</b> Plain visual evaluation of the J-sign revealed fair interrater reliability. The haptic visual assessment of the J-sign and the digital photo application tool yielded good interrater reliability. The results indicate that haptic visual assessment of J-sign should be implemented in daily clinical practice and used to communicate findings between and among physicians and studies.

Journal of Clinical MedicineVol. 14(23)
Heidelberg University (DE), Ludwigshafen University of Business and Society (DE), ARCUS Sports Clinic (DE), Klinikum Ludwigshafen (DE), Saarland University (DE)
Openalex Percentile: Top 62%
Lower Extremity Biomechanics and Pathologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.