Comparative Safety and Efficacy of Patient-Specific Versus Hand-Molded Implants in Cranioplasty: A Systematic Review and Meta-Analysis

<b>Background/Objectives:</b> Cranioplasty (CP) is associated with high complication rates (20-50%), and the optimal choice between patient-specific implants (PSIs) and hand-molded (HM) alternatives remains debated. This systematic review and meta-analysis aims to compare surgical and postoperative outcomes between PSIs and HM implants. <b>Methods:</b> A systematic search was performed in three databases to identify studies reporting surgical site infection (SSI), implant removal, reoperation, operative time or cosmetic outcome for PSIs and/or HM implants. Two-arm studies of the same material were analyzed separately from pooled single- and two-arm studies. <b>Results:</b> 125 observational studies involving 10,034 patients were included. In two-arm comparisons, PSIs reduced implant removal for titanium (OR 0.34, <i>p</i> = 0.053) and PMMA (OR 0.56, <i>p</i> = 0.188), while SSI rates showed no meaningful difference between groups. In one-arm analyses, PSIs demonstrated lower explantation probabilities (titanium 6.1%, PMMA 7.9%) compared with HM alternatives (titanium 9.9%, PMMA 14.2%), alongside shorter operation times and fewer reoperations. Cosmetic outcomes consistently favored PSIs. <b>Conclusions:</b> PSIs demonstrate advantages in efficiency, durability, and esthetics compared with HM implants, supporting their preferential use where resources allow. HM implants remain a cost-effective option in resource-limited settings. Due to the observational nature of the included studies and differences in study populations across arms, the findings should be interpreted with caution.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-12-06
DOI
https://doi.org/10.3390/jcm14248655
Primary Topic
Traumatic Brain Injury and Neurovascular Disturbances
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Safety and Efficacy of Patient-Specific Versus Hand-Molded Implants in Cranioplasty: A Systematic Review and Meta-Analysis

Zsolt Németh, Márton Kivovics, Bruna Guimaraes Carvalho, Boglárka Szentes et al.
Journal of Clinical Medicine
Traumatic Brain Injury and Neurovascular Disturbances
article

Comparative Safety and Efficacy of Patient-Specific Versus Hand-Molded Implants in Cranioplasty: A Systematic Review and Meta-Analysis

Zsolt Németh, Márton Kivovics, Bruna Guimaraes Carvalho, Boglárka Szentes, Gergely Agócs, Mihály Vaszilkó, Alexander Schulze Wenning, Elias-Leon Nolden, Péter Hegyi, László Köles, Katarina Sofia Barkovskij‐Jakobsen
article en

Abstract

<b>Background/Objectives:</b> Cranioplasty (CP) is associated with high complication rates (20-50%), and the optimal choice between patient-specific implants (PSIs) and hand-molded (HM) alternatives remains debated. This systematic review and meta-analysis aims to compare surgical and postoperative outcomes between PSIs and HM implants. <b>Methods:</b> A systematic search was performed in three databases to identify studies reporting surgical site infection (SSI), implant removal, reoperation, operative time or cosmetic outcome for PSIs and/or HM implants. Two-arm studies of the same material were analyzed separately from pooled single- and two-arm studies. <b>Results:</b> 125 observational studies involving 10,034 patients were included. In two-arm comparisons, PSIs reduced implant removal for titanium (OR 0.34, <i>p</i> = 0.053) and PMMA (OR 0.56, <i>p</i> = 0.188), while SSI rates showed no meaningful difference between groups. In one-arm analyses, PSIs demonstrated lower explantation probabilities (titanium 6.1%, PMMA 7.9%) compared with HM alternatives (titanium 9.9%, PMMA 14.2%), alongside shorter operation times and fewer reoperations. Cosmetic outcomes consistently favored PSIs. <b>Conclusions:</b> PSIs demonstrate advantages in efficiency, durability, and esthetics compared with HM implants, supporting their preferential use where resources allow. HM implants remain a cost-effective option in resource-limited settings. Due to the observational nature of the included studies and differences in study populations across arms, the findings should be interpreted with caution.

Journal of Clinical MedicineVol. 14(24)
Semmelweis University (HU), University of Pecs (HU)
Openalex Percentile: Top 46%
Traumatic Brain Injury and Neurovascular Disturbances
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.