In Vivo Accuracy Assessment of Two Intraoral Scanners Using Open-Source Software: A Comparative Full-Arch Pilot Study

Background: The precision of intraoral scanners (IOSs) is a key factor in ensuring the reliability of digital impressions, particularly in full-arch workflows. Although proprietary metrology tools are generally employed for scanner validation, open-source platforms could provide a cost-effective alternative for clinical research. Methods: This in vivo study compared the precision of two IOSs—3Shape TRIOS 3 and Planmeca Emerald S—using an open-source analytical workflow based on Autodesk Meshmixer and CloudCompare. A single healthy subject underwent five consecutive full-arch scans per device. Digital models were trimmed, aligned by manual landmarking and iterative closest-point refinement, and analyzed at six deviation thresholds (<0.01 mm to <0.4 mm). The percentage of surface points within clinically acceptable limits (<0.3 mm) was compared using paired t-tests. Results: TRIOS 3 exhibited significantly higher repeatability than Planmeca Emerald S (p < 0.001). At the <0.3 mm threshold, 99.3% ± 0.4% of points were within tolerance for TRIOS 3 versus 92.9% ± 6.8% for Planmeca. At the <0.1 mm threshold, values were 89.6% ± 5.7% and 47.3% ± 13.7%, respectively. Colorimetric deviation maps confirmed greater spatial consistency of TRIOS 3, particularly in posterior regions. Conclusions: Both scanners achieved clinically acceptable precision for full-arch impressions; however, TRIOS 3 demonstrated superior repeatability and lower variability. The proposed open-source workflow proved feasible and reliable, offering an accessible and reproducible method for IOS performance assessment in clinical settings.

Authors

Institutions

Publication Details

Journal
Oral
Published
2025-12-02
DOI
https://doi.org/10.3390/oral5040097
Citations
2
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
3.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Vivo Accuracy Assessment of Two Intraoral Scanners Using Open-Source Software: A Comparative Full-Arch Pilot Study

Salvatore De Vita, Fabio Salmeri, Roberta Gasparro, Roberto Lo Giudice et al.
2 citations
Oral
Dental materials and restorations
3.35
article

In Vivo Accuracy Assessment of Two Intraoral Scanners Using Open-Source Software: A Comparative Full-Arch Pilot Study

Salvatore De Vita, Fabio Salmeri, Roberta Gasparro, Roberto Lo Giudice, Ettore Lupi, Francesco Puleio, Ines Urbano
article en
2 citations

Abstract

Background: The precision of intraoral scanners (IOSs) is a key factor in ensuring the reliability of digital impressions, particularly in full-arch workflows. Although proprietary metrology tools are generally employed for scanner validation, open-source platforms could provide a cost-effective alternative for clinical research. Methods: This in vivo study compared the precision of two IOSs—3Shape TRIOS 3 and Planmeca Emerald S—using an open-source analytical workflow based on Autodesk Meshmixer and CloudCompare. A single healthy subject underwent five consecutive full-arch scans per device. Digital models were trimmed, aligned by manual landmarking and iterative closest-point refinement, and analyzed at six deviation thresholds (<0.01 mm to <0.4 mm). The percentage of surface points within clinically acceptable limits (<0.3 mm) was compared using paired t-tests. Results: TRIOS 3 exhibited significantly higher repeatability than Planmeca Emerald S (p < 0.001). At the <0.3 mm threshold, 99.3% ± 0.4% of points were within tolerance for TRIOS 3 versus 92.9% ± 6.8% for Planmeca. At the <0.1 mm threshold, values were 89.6% ± 5.7% and 47.3% ± 13.7%, respectively. Colorimetric deviation maps confirmed greater spatial consistency of TRIOS 3, particularly in posterior regions. Conclusions: Both scanners achieved clinically acceptable precision for full-arch impressions; however, TRIOS 3 demonstrated superior repeatability and lower variability. The proposed open-source workflow proved feasible and reliable, offering an accessible and reproducible method for IOS performance assessment in clinical settings.

OralVol. 5(4)
University of Messina (IT), University of L'Aquila (IT), University of Naples Federico II (IT)
Openalex Percentile: Top 7%
Dental materials and restorations
3.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.