Prosthetic Cap-Free Implant Restorations: Five-Year Clinical Performance with Mechanical Verification

<b>Background:</b> The use of prosthetic caps in screw-retained implant restorations aims to enhance passivity and protect abutment threads; however, these components may increase prosthetic volume and impair esthetics. Advances in high-strength zirconia have raised the question of whether such caps remain necessary. <b>Methods:</b> A retrospective clinical analysis was conducted on 20 partial screw-retained zirconia restorations comparing cases fabricated with and without a prosthetic cap. All restorations were followed for 3-5 years. Clinical outcomes included screw stability, marginal adaptation, esthetics (VAS), hygiene access, and biological response. A supplementary mechanical verification was performed on four standardized zirconia crowns fabricated through digital and conventional impression workflows to qualitatively assess their behavior under 30 N·cm torque and compressive loading above 1200 MPa. <b>Results:</b> Throughout follow-up, no mechanical or biological complications were recorded in either group. One restoration with a cap required screw re-tightening, while none failed in the cap-free group. Radiographic analysis showed smaller mean marginal gaps in cap-free restorations (0.183 mm) compared to those with caps (0.289 mm; <i>p</i> < 0.01). Esthetic satisfaction scores were higher in the cap-free group (VAS = 9.3 ± 0.1 vs. 8.2 ± 0.1; <i>p</i> < 0.001). Mechanical verification confirmed that all zirconia crowns tolerated torque and compressive loads without visible fracture or deformation. <b>Conclusions:</b> Within the study limitations, cap-free screw-retained zirconia restorations exhibited excellent 5-year clinical stability, improved esthetics, and better hygiene access compared with capped designs. The small-scale mechanical verification supported the clinical findings, indicating that cap omission does not compromise mechanical performance when accurate fit and digital workflow precision are ensured.

Authors

Institutions

Publication Details

Journal
Dentistry Journal
Published
2025-12-08
DOI
https://doi.org/10.3390/dj13120586
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prosthetic Cap-Free Implant Restorations: Five-Year Clinical Performance with Mechanical Verification

Laura Cristina Rusu, E Bratu, Ioan-Achim Borșanu, Sergiu-Manuel Antonie
Dentistry Journal
Dental Implant Techniques and Outcomes
article

Prosthetic Cap-Free Implant Restorations: Five-Year Clinical Performance with Mechanical Verification

Laura Cristina Rusu, E Bratu, Ioan-Achim Borșanu, Sergiu-Manuel Antonie
article en

Abstract

<b>Background:</b> The use of prosthetic caps in screw-retained implant restorations aims to enhance passivity and protect abutment threads; however, these components may increase prosthetic volume and impair esthetics. Advances in high-strength zirconia have raised the question of whether such caps remain necessary. <b>Methods:</b> A retrospective clinical analysis was conducted on 20 partial screw-retained zirconia restorations comparing cases fabricated with and without a prosthetic cap. All restorations were followed for 3-5 years. Clinical outcomes included screw stability, marginal adaptation, esthetics (VAS), hygiene access, and biological response. A supplementary mechanical verification was performed on four standardized zirconia crowns fabricated through digital and conventional impression workflows to qualitatively assess their behavior under 30 N·cm torque and compressive loading above 1200 MPa. <b>Results:</b> Throughout follow-up, no mechanical or biological complications were recorded in either group. One restoration with a cap required screw re-tightening, while none failed in the cap-free group. Radiographic analysis showed smaller mean marginal gaps in cap-free restorations (0.183 mm) compared to those with caps (0.289 mm; <i>p</i> < 0.01). Esthetic satisfaction scores were higher in the cap-free group (VAS = 9.3 ± 0.1 vs. 8.2 ± 0.1; <i>p</i> < 0.001). Mechanical verification confirmed that all zirconia crowns tolerated torque and compressive loads without visible fracture or deformation. <b>Conclusions:</b> Within the study limitations, cap-free screw-retained zirconia restorations exhibited excellent 5-year clinical stability, improved esthetics, and better hygiene access compared with capped designs. The small-scale mechanical verification supported the clinical findings, indicating that cap omission does not compromise mechanical performance when accurate fit and digital workflow precision are ensured.

Dentistry JournalVol. 13(12)
Victor Babeș University of Medicine and Pharmacy Timișoara (RO)
Openalex Percentile: Top 46%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.