An approach to in vivo low-magnification optical coherence tomography for selective monitoring of tissue glucose concentration

The low-magnification optical coherence tomography (LM-OCT) is expected to enable the quantification of tissue glucose concentration (TGC) by maintaining high spatial resolution while reducing artifacts caused by tissue heterogeneity. In the present study, we report the practical application of LM-OCT using a conventional OCT system, i.e., without compromising spatial resolution, for the selective monitoring of changes in TGC through <i>in vivo</i> experiments using a hairless rat model. A commercially available high-spatial resolution OCT device with a center wavelength of 1300 nm was used to detect the three-dimensional (3D) skin surface structure and the scattering coefficient related to the OCT slope. The grand-averaged OCT signal was employed to estimate the OCT slope, while the original high-resolution OCT signals were used to reconstruct the 3D-structural image. A strong linear correlation was observed between changes in the OCT slope and that in TGC, but not with 2-deoxy-glucose, lactate, or Intralipos (soybean oil).

Authors

Institutions

Publication Details

Journal
MethodsX
Published
2025-12-08
DOI
https://doi.org/10.1016/j.mex.2025.103752
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An approach to in vivo low-magnification optical coherence tomography for selective monitoring of tissue glucose concentration

Akitoshi Seiyama, Fengcheng Wei, Masato Ohmi
MethodsX
Optical Coherence Tomography Applications
article

An approach to in vivo low-magnification optical coherence tomography for selective monitoring of tissue glucose concentration

Akitoshi Seiyama, Fengcheng Wei, Masato Ohmi
article en

Abstract

The low-magnification optical coherence tomography (LM-OCT) is expected to enable the quantification of tissue glucose concentration (TGC) by maintaining high spatial resolution while reducing artifacts caused by tissue heterogeneity. In the present study, we report the practical application of LM-OCT using a conventional OCT system, i.e., without compromising spatial resolution, for the selective monitoring of changes in TGC through <i>in vivo</i> experiments using a hairless rat model. A commercially available high-spatial resolution OCT device with a center wavelength of 1300 nm was used to detect the three-dimensional (3D) skin surface structure and the scattering coefficient related to the OCT slope. The grand-averaged OCT signal was employed to estimate the OCT slope, while the original high-resolution OCT signals were used to reconstruct the 3D-structural image. A strong linear correlation was observed between changes in the OCT slope and that in TGC, but not with 2-deoxy-glucose, lactate, or Intralipos (soybean oil).

MethodsXVol. 16
The University of Osaka (JP)
Openalex Percentile: Top 62%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.