Polymer nanofiber-based electrodes for tyrosinase detection in melanoma diagnosis

• Disposable electrochemical biosensor detects tyrosinase for early melanoma diagnosis. • Aligned PA6/PPy nanofibers enhance sensitivity (LOD: 0.029 mg/mL in serum). • High biocompatibility and stability in synthetic ISF and human serum. • Cost-effective, scalable fabrication via electrospinning and polymerization. • Potential for integration into point-of-care melanoma screening devices. The rising global incidence of melanoma and its high mortality rates due to late diagnosis demand rapid, sensitive, and non-invasive diagnostic tools. Here, we introduce a disposable electrochemical biosensor that exploits the synergistic properties of electrospun polyamide 6 (PA6) and conductive polypyrrole (PPy) nanofibers for detecting tyrosinase (Tyr). The biosensor integrates the high surface area and tunable morphology of PA6 nanofibers (random and aligned) with highly conductive PPy, fabricated via electrospinning, and polymerization onto indium tin oxide (ITO) electrodes to ensure selective Tyr binding. Electrochemical testing in synthetic interstitial fluid (ISF) and human serum reveals a linear response to Tyr (0.1–0.9 mg/mL), with the aligned nanofiber configuration achieving high limits of detection (LOD) of 0.03 mg/mL (ISF) and 0.029 mg/mL (serum), alongside sensitivities of 95.97 and 76.60 μA·mg⁻¹·mL·cm⁻², respectively. The concentration-dependent current response highlights the biosensor’s high sensitivity, stability, and biocompatibility, proving its potential for non-invasive, early-stage melanoma detection in complex biological environments. This work paves the way for scalable, cost-effective melanoma screening, with future studies aimed at clinical validation and integration into point-of-care devices to improve patient outcomes globally.

Authors

Institutions

Publication Details

Journal
Sensors and Actuators Reports
Published
2025-12-08
DOI
https://doi.org/10.1016/j.snr.2025.100416
Citations
1
Primary Topic
melanin and skin pigmentation
Type
article
Field-Weighted Citation Impact
1.15
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Polymer nanofiber-based electrodes for tyrosinase detection in melanoma diagnosis

Alireza Sanati, Nazanin Poursharifi, Dariush Semnani, Ali A. Ensafi et al.
1 citations
Sensors and Actuators Reports
melanin and skin pigmentation
1.15
article

Polymer nanofiber-based electrodes for tyrosinase detection in melanoma diagnosis

Alireza Sanati, Nazanin Poursharifi, Dariush Semnani, Ali A. Ensafi, Hossein Fashandi, Onur Parlak
article en
1 citations

Abstract

• Disposable electrochemical biosensor detects tyrosinase for early melanoma diagnosis. • Aligned PA6/PPy nanofibers enhance sensitivity (LOD: 0.029 mg/mL in serum). • High biocompatibility and stability in synthetic ISF and human serum. • Cost-effective, scalable fabrication via electrospinning and polymerization. • Potential for integration into point-of-care melanoma screening devices. The rising global incidence of melanoma and its high mortality rates due to late diagnosis demand rapid, sensitive, and non-invasive diagnostic tools. Here, we introduce a disposable electrochemical biosensor that exploits the synergistic properties of electrospun polyamide 6 (PA6) and conductive polypyrrole (PPy) nanofibers for detecting tyrosinase (Tyr). The biosensor integrates the high surface area and tunable morphology of PA6 nanofibers (random and aligned) with highly conductive PPy, fabricated via electrospinning, and polymerization onto indium tin oxide (ITO) electrodes to ensure selective Tyr binding. Electrochemical testing in synthetic interstitial fluid (ISF) and human serum reveals a linear response to Tyr (0.1–0.9 mg/mL), with the aligned nanofiber configuration achieving high limits of detection (LOD) of 0.03 mg/mL (ISF) and 0.029 mg/mL (serum), alongside sensitivities of 95.97 and 76.60 μA·mg⁻¹·mL·cm⁻², respectively. The concentration-dependent current response highlights the biosensor’s high sensitivity, stability, and biocompatibility, proving its potential for non-invasive, early-stage melanoma detection in complex biological environments. This work paves the way for scalable, cost-effective melanoma screening, with future studies aimed at clinical validation and integration into point-of-care devices to improve patient outcomes globally.

Sensors and Actuators ReportsVol. 11
Isfahan University of Medical Sciences (IR), Isfahan University of Technology (IR), Karolinska Institutet (SE)
Openalex Percentile: Top 17%
melanin and skin pigmentation
1.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.