Identifying Volar Locking Plates on Plain Radiographs: Can Artificial Intelligence Models ‘Beat’ Clinicians?

Background Hand surgeons are frequently required to identify volar locking plates on plain radiographs. This is important, for example, when planning what equipment is required for revision, implant removal or periprosthetic fractures, but it can be challenging, especially if surgery took place in another hospital or even country. Artificial intelligence (AI) clearly has potential in medical image recognition, but its role in orthopaedic implant identification currently remains uncertain. This study compared the performance of an openly available AI model, ChatGPT 5, with that of experienced hand consultants. Methods Fifty-two radiographs of distal radius plates from 10 major implant manufacturers were obtained from open-access sources. An AI programme (ChatGPT 5) and five hand consultants independently identified the manufacturer for each radiograph. Accuracy was calculated for each rater. Pairwise comparisons between AI and each consultant were assessed using McNemar's test, and a standard logistic regression with clustered standard errors was fitted to compare AI with consultants as a group. Results ChatGPT5 correctly identified just 3 of 52 radiographs (5.8% accuracy). Consultant accuracies ranged between 13.5 and 46.2% (mean 30.8% ± 11.1). McNemar's test showed that Consultants 1, 3, 4 and 5 significantly outperformed the AI (p < 0.01), while Consultant 2 did not (p = 0.289). In a standard logistic regression with clustered standard errors, the human cohort had 7.26 times higher odds of correct identification compared with the AI (OR 7.26, 95% CI 2.27-23.18, p < 0.001). Conclusion Identifying volar locking distal radius plates from plain radiographs remains difficult, even for experienced surgeons and even the 'best' consultant identified under 50% correctly. That notwithstanding, humans were on average seven times better than ChatGPT 5 which only identified just over 5% correctly. While current non-specialised AI tools are not suitable for implant identification currently, dedicated AI models trained on curated orthopaedic datasets may hold promise for future clinical use.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-12-08
DOI
https://doi.org/10.7759/cureus.98715
Primary Topic
Artificial Intelligence in Healthcare and Education
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Identifying Volar Locking Plates on Plain Radiographs: Can Artificial Intelligence Models ‘Beat’ Clinicians?

M.I. Arsan, Adam Stoneham, Priyanshu Saha, Adelin Albert et al.
Cureus
Artificial Intelligence in Healthcare and Education
article

Identifying Volar Locking Plates on Plain Radiographs: Can Artificial Intelligence Models ‘Beat’ Clinicians?

M.I. Arsan, Adam Stoneham, Priyanshu Saha, Adelin Albert, Alex Nicholls, Duncan Avis, Medhat Zekry
article en

Abstract

Background Hand surgeons are frequently required to identify volar locking plates on plain radiographs. This is important, for example, when planning what equipment is required for revision, implant removal or periprosthetic fractures, but it can be challenging, especially if surgery took place in another hospital or even country. Artificial intelligence (AI) clearly has potential in medical image recognition, but its role in orthopaedic implant identification currently remains uncertain. This study compared the performance of an openly available AI model, ChatGPT 5, with that of experienced hand consultants. Methods Fifty-two radiographs of distal radius plates from 10 major implant manufacturers were obtained from open-access sources. An AI programme (ChatGPT 5) and five hand consultants independently identified the manufacturer for each radiograph. Accuracy was calculated for each rater. Pairwise comparisons between AI and each consultant were assessed using McNemar's test, and a standard logistic regression with clustered standard errors was fitted to compare AI with consultants as a group. Results ChatGPT5 correctly identified just 3 of 52 radiographs (5.8% accuracy). Consultant accuracies ranged between 13.5 and 46.2% (mean 30.8% ± 11.1). McNemar's test showed that Consultants 1, 3, 4 and 5 significantly outperformed the AI (p < 0.01), while Consultant 2 did not (p = 0.289). In a standard logistic regression with clustered standard errors, the human cohort had 7.26 times higher odds of correct identification compared with the AI (OR 7.26, 95% CI 2.27-23.18, p < 0.001). Conclusion Identifying volar locking distal radius plates from plain radiographs remains difficult, even for experienced surgeons and even the 'best' consultant identified under 50% correctly. That notwithstanding, humans were on average seven times better than ChatGPT 5 which only identified just over 5% correctly. While current non-specialised AI tools are not suitable for implant identification currently, dedicated AI models trained on curated orthopaedic datasets may hold promise for future clinical use.

CureusVol. 17(12)
Hampshire Hospitals NHS Foundation Trust (GB), Homerton University Hospital (GB)
Openalex Percentile: Top 67%
Artificial Intelligence in Healthcare and Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.