Drug Delivery Device Design and Compatibility with Nitrogen Dioxide Gas Sterilization

Polymeric materials have become important components in prefilled syringes, drug delivery systems, and advanced medical devices. <b>Background/Objectives</b>: Nitrogen dioxide gas is used for the terminal sterilization of drug delivery systems. For the implementation of sterilization methods, compatibility with materials must be demonstrated such that the materials maintain product requirements and specifications after sterilization and at the time of use (i.e., product shelf life). <b>Methods</b>: Commonly used polymers were selected based on their chemical structures to provide insight into the nature of reactions that occur at the temperature and NO<sub>2</sub> concentration levels used in the sterilization process. After exposure to the NO<sub>2</sub> process, materials were evaluated for chemical, mechanical, and biocompatibility properties. <b>Results</b>: In this paper, we demonstrated the compatibility of polymers comprising carbonyl, unsaturated ester, and ketone groups which have been used in medical devices sterilized with NO<sub>2</sub>. No significant chemical or physical changes were observed upon the treatment of Amorphous Polyester, Polysulfone (PSU), Polycarbonate (PC), PolyEtherEtherKetone (PEEK), PolyArylEtherKetone (PAEK), and Polypropylene (PP) with NO<sub>2</sub> at a sterilization temperature of 20 °C. At this relatively low sterilization temperature, the reactions of NO<sub>2</sub> with the polymer do not typically occur because the activation energies of these reactions require much higher temperatures. <b>Conclusions</b>: Not all materials will be compatible with NO<sub>2</sub> sterilization, and even with the established data, many devices will need to have their polymers evaluated for compatibility before moving to NO<sub>2</sub> sterilization. These results will provide guidance to device designers selecting materials for new drug delivery devices and to regulators that review the safety and efficacy of these devices.

Authors

Institutions

Publication Details

Journal
Pharmaceuticals
Published
2025-12-08
DOI
https://doi.org/10.3390/ph18121869
Primary Topic
Polymer Science and PVC
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Drug Delivery Device Design and Compatibility with Nitrogen Dioxide Gas Sterilization

Minufar Abdollahi Khabisi, T E Sadler, David Opie, Aiysha Ashfaq et al.
Pharmaceuticals
Polymer Science and PVC
article

Drug Delivery Device Design and Compatibility with Nitrogen Dioxide Gas Sterilization

Minufar Abdollahi Khabisi, T E Sadler, David Opie, Aiysha Ashfaq, Mohamad Al‐Sheikhly, T. A. Bateman, Narayan Chandra Ray, Nusrat Sarwahrdy, Delaney Lisco, Julia Diane Schexnayder
article en

Abstract

Polymeric materials have become important components in prefilled syringes, drug delivery systems, and advanced medical devices. <b>Background/Objectives</b>: Nitrogen dioxide gas is used for the terminal sterilization of drug delivery systems. For the implementation of sterilization methods, compatibility with materials must be demonstrated such that the materials maintain product requirements and specifications after sterilization and at the time of use (i.e., product shelf life). <b>Methods</b>: Commonly used polymers were selected based on their chemical structures to provide insight into the nature of reactions that occur at the temperature and NO<sub>2</sub> concentration levels used in the sterilization process. After exposure to the NO<sub>2</sub> process, materials were evaluated for chemical, mechanical, and biocompatibility properties. <b>Results</b>: In this paper, we demonstrated the compatibility of polymers comprising carbonyl, unsaturated ester, and ketone groups which have been used in medical devices sterilized with NO<sub>2</sub>. No significant chemical or physical changes were observed upon the treatment of Amorphous Polyester, Polysulfone (PSU), Polycarbonate (PC), PolyEtherEtherKetone (PEEK), PolyArylEtherKetone (PAEK), and Polypropylene (PP) with NO<sub>2</sub> at a sterilization temperature of 20 °C. At this relatively low sterilization temperature, the reactions of NO<sub>2</sub> with the polymer do not typically occur because the activation energies of these reactions require much higher temperatures. <b>Conclusions</b>: Not all materials will be compatible with NO<sub>2</sub> sterilization, and even with the established data, many devices will need to have their polymers evaluated for compatibility before moving to NO<sub>2</sub> sterilization. These results will provide guidance to device designers selecting materials for new drug delivery devices and to regulators that review the safety and efficacy of these devices.

PharmaceuticalsVol. 18(12)
University of Maryland, College Park (US)
Maryland Industrial Partnerships
Openalex Percentile: Top 65%
Polymer Science and PVC
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.