Three-Station Non-Contrast MR Angiography of the Lower Extremities Using Standard and Centric Fresh Blood Imaging

<b>Background</b>: Peripheral artery disease (PAD) is a manifestation of atherosclerosis that affects the extremities, leading to reduced perfusion and functional impairment. Non-contrast magnetic resonance angiography (NC-MRA) provides a safe and quantitative approach for early detection of PAD without the risks associated with contrast agents. The purpose of this study was to demonstrate the application of standard and centric <i>ky</i>-<i>kz</i> FBI techniques for rapid three-station NC-MRA of the entire lower extremity. <b>Methods</b>: This prospective cross-sectional study compared standard three-station fresh blood imaging (sFBI) with centric <i>ky</i>-<i>kz</i> ordered fresh blood imaging (cFBI) sequences in 10 healthy subjects and 3 patients with PAD (age range: 23-79 years; 7 females) using a 3-Tesla magnetic resonance imaging (MRI) system. Both sequences were acquired at the iliac, femoral, and tibial stations. Image quality (0-4 scale), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were evaluated. Statistical analysis was performed using repeated-measures analysis of variance (ANOVA) with significance set at α = 0.05. <b>Results</b>: Image quality did not differ significantly between sFBI and cFBI (<i>p</i> = 1.0). The iliac station exhibited lower image quality than the femoral station (<i>p</i> < 0.01). In a PAD patient with an iliac stent, cFBI preserved good image quality in the femoral and tibial stations, whereas sFBI was affected by N/2 aliasing artifacts. Both methods failed to visualize the stented iliac segment. Compared to sFBI, cFBI yielded significantly lower SNR (<i>p</i> < 0.01) and CNR (<i>p</i> < 0.001) but reduced total scan time by approximately 40% (468 s vs. 291 s). <b>Conclusions</b>: Three-station non-contrast FBI MRA of the peripheral arteries is feasible. The cFBI sequence substantially shortens scan time without compromising diagnostic image quality, offering practical advantages for clinical implementation, improved patient comfort, and reduced motion artifacts.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-12-06
DOI
https://doi.org/10.3390/s25247429
Primary Topic
Peripheral Artery Disease Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Three-Station Non-Contrast MR Angiography of the Lower Extremities Using Standard and Centric Fresh Blood Imaging

Won C. Bae, Vadim Malis, Ann C. Gaffey, Yoshiki Kuwatsuru et al.
Sensors
Peripheral Artery Disease Management
article

Three-Station Non-Contrast MR Angiography of the Lower Extremities Using Standard and Centric Fresh Blood Imaging

Won C. Bae, Vadim Malis, Ann C. Gaffey, Yoshiki Kuwatsuru, Mitsue Miyazaki, Anya Mesa, Katsumi Nakamura
article en

Abstract

<b>Background</b>: Peripheral artery disease (PAD) is a manifestation of atherosclerosis that affects the extremities, leading to reduced perfusion and functional impairment. Non-contrast magnetic resonance angiography (NC-MRA) provides a safe and quantitative approach for early detection of PAD without the risks associated with contrast agents. The purpose of this study was to demonstrate the application of standard and centric <i>ky</i>-<i>kz</i> FBI techniques for rapid three-station NC-MRA of the entire lower extremity. <b>Methods</b>: This prospective cross-sectional study compared standard three-station fresh blood imaging (sFBI) with centric <i>ky</i>-<i>kz</i> ordered fresh blood imaging (cFBI) sequences in 10 healthy subjects and 3 patients with PAD (age range: 23-79 years; 7 females) using a 3-Tesla magnetic resonance imaging (MRI) system. Both sequences were acquired at the iliac, femoral, and tibial stations. Image quality (0-4 scale), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were evaluated. Statistical analysis was performed using repeated-measures analysis of variance (ANOVA) with significance set at α = 0.05. <b>Results</b>: Image quality did not differ significantly between sFBI and cFBI (<i>p</i> = 1.0). The iliac station exhibited lower image quality than the femoral station (<i>p</i> < 0.01). In a PAD patient with an iliac stent, cFBI preserved good image quality in the femoral and tibial stations, whereas sFBI was affected by N/2 aliasing artifacts. Both methods failed to visualize the stented iliac segment. Compared to sFBI, cFBI yielded significantly lower SNR (<i>p</i> < 0.01) and CNR (<i>p</i> < 0.001) but reduced total scan time by approximately 40% (468 s vs. 291 s). <b>Conclusions</b>: Three-station non-contrast FBI MRA of the peripheral arteries is feasible. The cFBI sequence substantially shortens scan time without compromising diagnostic image quality, offering practical advantages for clinical implementation, improved patient comfort, and reduced motion artifacts.

SensorsVol. 25(24)
Kyushu Kyoritsu University (JP), Juntendo University (JP), University of California San Diego (US)
Openalex Percentile: Top 42%
Peripheral Artery Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.