A cryogenic uniaxial strain cell for strain-dependent measurements

We present the design, implementation, and validation of a cryo-compatible uniaxial strain cell for strain-dependent investigations in quantum materials. The cell is actuated by three large-format piezoelectric stacks and achieves maximum sample displacements of about 38 μm at room temperature and 1.7 μm at 5 K. The compact geometry provides an extended mounting area that facilitates the investigation of comparatively large samples and allows flexible contact configurations. The actuators, with a cross-sectional area of 7 × 7 mm2, ensure high mechanical stability and enable the application of substantial forces. A key advantage of the design is the high-resolution capacitive displacement sensor, which enables precise in situ strain control with excellent temporal resolution, allowing for dynamic strain tracking beyond the capabilities of conventional setups. To operate the strain cell over a broad temperature range from 4.2 to 300 K, a modular measurement probe was developed, allowing efficient thermal coupling and integration into cryogenic environments. The functionality and precision of the setup were demonstrated by elastoresistance measurements on the iron-based superconductor BaFe2As2 along the [110] direction. The results were compared to those obtained using the conventional approach, in which the sample is directly glued onto a single piezoelectric actuator, showing excellent agreement in amplitude and temperature dependence of the elastoresistance coefficient. Additional tests revealed that the system remains robust under mechanical vibrations introduced by vacuum pumps, enabling stable operation even with liquid nitrogen cooling. Beyond elastoresistivity, the combination of high mechanical stability and time-resolved strain detection makes the presented setup a versatile platform for a broad range of strain-dependent experiments, including future implementations of thermodynamic techniques such as elastocaloric measurements.

Authors

Institutions

Publication Details

Journal
AIP Advances
Published
2025-12-01
DOI
https://doi.org/10.1063/5.0291096
Primary Topic
Iron-based superconductors research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A cryogenic uniaxial strain cell for strain-dependent measurements

Swantje Bargmann, Amir A. Haghighirad, C. Heß, Jana Wilmers et al.
AIP Advances
Iron-based superconductors research
article

A cryogenic uniaxial strain cell for strain-dependent measurements

Swantje Bargmann, Amir A. Haghighirad, C. Heß, Jana Wilmers, Franz Eckelt, T. Wolf, Ralph Wagner, Isidoro Cavallaro
article en

Abstract

We present the design, implementation, and validation of a cryo-compatible uniaxial strain cell for strain-dependent investigations in quantum materials. The cell is actuated by three large-format piezoelectric stacks and achieves maximum sample displacements of about 38 μm at room temperature and 1.7 μm at 5 K. The compact geometry provides an extended mounting area that facilitates the investigation of comparatively large samples and allows flexible contact configurations. The actuators, with a cross-sectional area of 7 × 7 mm2, ensure high mechanical stability and enable the application of substantial forces. A key advantage of the design is the high-resolution capacitive displacement sensor, which enables precise in situ strain control with excellent temporal resolution, allowing for dynamic strain tracking beyond the capabilities of conventional setups. To operate the strain cell over a broad temperature range from 4.2 to 300 K, a modular measurement probe was developed, allowing efficient thermal coupling and integration into cryogenic environments. The functionality and precision of the setup were demonstrated by elastoresistance measurements on the iron-based superconductor BaFe2As2 along the [110] direction. The results were compared to those obtained using the conventional approach, in which the sample is directly glued onto a single piezoelectric actuator, showing excellent agreement in amplitude and temperature dependence of the elastoresistance coefficient. Additional tests revealed that the system remains robust under mechanical vibrations introduced by vacuum pumps, enabling stable operation even with liquid nitrogen cooling. Beyond elastoresistivity, the combination of high mechanical stability and time-resolved strain detection makes the presented setup a versatile platform for a broad range of strain-dependent experiments, including future implementations of thermodynamic techniques such as elastocaloric measurements.

AIP AdvancesVol. 15(12)
University of Wuppertal (DE), University of Applied Sciences Stralsund (DE)
Openalex Percentile: Top 71%
Iron-based superconductors research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.