Assessment of Cerebrospinal Fluid Flow Patterns Using Time‐Spatial Labeling Inversion Pulse Sequence in a Dog With Chiari‐Like Malformation and Syringomyelia

A 5-year-old toy poodle was referred for progressive non-ambulatory tetraparesis caused by cervicothoracic syringomyelia associated with Chiari-like malformation. At presentation, the cerebrospinal fluid (CSF) flow pattern was atypical on time-spatial labeling inversion pulse images with evidence of greater volume flow through the mesencephalic aqueduct and atypical to-and-fro flow in the fourth ventricle and into the syrinx. In this dog, the definition of CSF flow pattern using this imaging technique before surgery aided in classifying pathogenesis and suggested the utility of ventriculoperitoneal shunting, which normalized CSF flow and resulted in a good clinical outcome.

Authors

Institutions

Publication Details

Journal
Veterinary Radiology & Ultrasound
Published
2025-12-08
DOI
https://doi.org/10.1111/vru.70119
Primary Topic
Spinal Dysraphism and Malformations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Cerebrospinal Fluid Flow Patterns Using Time‐Spatial Labeling Inversion Pulse Sequence in a Dog With Chiari‐Like Malformation and Syringomyelia

Daisuke Ito, Nick D. Jeffery, Chieko Ishikawa
Veterinary Radiology & Ultrasound
Spinal Dysraphism and Malformations
article

Assessment of Cerebrospinal Fluid Flow Patterns Using Time‐Spatial Labeling Inversion Pulse Sequence in a Dog With Chiari‐Like Malformation and Syringomyelia

Daisuke Ito, Nick D. Jeffery, Chieko Ishikawa
article en

Abstract

A 5-year-old toy poodle was referred for progressive non-ambulatory tetraparesis caused by cervicothoracic syringomyelia associated with Chiari-like malformation. At presentation, the cerebrospinal fluid (CSF) flow pattern was atypical on time-spatial labeling inversion pulse images with evidence of greater volume flow through the mesencephalic aqueduct and atypical to-and-fro flow in the fourth ventricle and into the syrinx. In this dog, the definition of CSF flow pattern using this imaging technique before surgery aided in classifying pathogenesis and suggested the utility of ventriculoperitoneal shunting, which normalized CSF flow and resulted in a good clinical outcome.

Veterinary Radiology & UltrasoundVol. 67(1)
Nihon University (JP), Texas A&M University (US)
Openalex Percentile: Top 50%
Spinal Dysraphism and Malformations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.