Multiscale Segmentation-Guided Diffusion Model for CBCT-to-CT Synthesis

To improve synthetic CT (sCT) generation from cone-beam CT (CBCT) in radiotherapy, we propose a multiscale segmentation-guided diffusion framework. The proposed model integrates anatomical priors across multiple spatial resolutions through a segmentation mask pyramid and introduces a scale-specific loss function to guide learning at each level. When evaluated on the SynthRAD2023 brain dataset, our model achieves a mean absolute error (MAE) of 61.82 HU, a peak signal-to-noise ratio (PSNR) of 32.05 dB, and a structural similarity index (SSIM) of 0.90, outperforming baseline models. These results suggest that multiscale anatomical guidance can improve the fidelity and anatomical consistency of sCT images, thus facilitating high-quality CBCT-to-CT translation in radiotherapy applications.

Authors

Institutions

Publication Details

Journal
Life
Published
2025-12-06
DOI
https://doi.org/10.3390/life15121871
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multiscale Segmentation-Guided Diffusion Model for CBCT-to-CT Synthesis

Wilfred Ngwa, Xue Feng, Kai Ding, Yemin Guo et al.
Life
Advanced Radiotherapy Techniques
article

Multiscale Segmentation-Guided Diffusion Model for CBCT-to-CT Synthesis

Wilfred Ngwa, Xue Feng, Kai Ding, Yemin Guo, Hamed Hooshangnejad, Quan Chen, Rui Zhang, Yi Luo
article en

Abstract

To improve synthetic CT (sCT) generation from cone-beam CT (CBCT) in radiotherapy, we propose a multiscale segmentation-guided diffusion framework. The proposed model integrates anatomical priors across multiple spatial resolutions through a segmentation mask pyramid and introduces a scale-specific loss function to guide learning at each level. When evaluated on the SynthRAD2023 brain dataset, our model achieves a mean absolute error (MAE) of 61.82 HU, a peak signal-to-noise ratio (PSNR) of 32.05 dB, and a structural similarity index (SSIM) of 0.90, outperforming baseline models. These results suggest that multiscale anatomical guidance can improve the fidelity and anatomical consistency of sCT images, thus facilitating high-quality CBCT-to-CT translation in radiotherapy applications.

LifeVol. 15(12)
University of Minnesota (US), Johns Hopkins University (US), Mayo Clinic Hospital (US), University of Virginia (US)
Openalex Percentile: Top 52%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.