Analysis of air temperatures in the cavity of double-skin facades
Non-optimal position of the blinds in double-skin facades can lead to overheating or heat loss. Spring temperature fluctuations and varying solar radiation provide ideal conditions for analysis, highlighting the impact of cavity geometry on thermal performance. This study examines the impact of blind positioning on the cavity air temperature in a double-skin facade during spring. Experimental measurements under different airflow modes showed that a smaller airflow circuit (mode A) produced greater temperature variations (0-7 K), whereas a larger circuit (mode D) resulted in smaller fluctuations (0-2 K).
Authors
- Erika Dolníková (ORCID: https://orcid.org/0000-0003-2042-3310)
- Martin Lopušniak (ORCID: https://orcid.org/0000-0002-8628-2322)
- Dominika Husáriková
Publication Details
- Published
- 2025-12-05
- DOI
- https://doi.org/10.13164/juniorstav.2025.26102
- Primary Topic
- Building Energy and Comfort Optimization
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Slovenská Akadémia Vied
- Vedecká Grantová Agentúra MŠVVaŠ SR a SAV