Monoblock or modular? Impact of stem design and conicity angle on long-term implant survival in revision total hip arthroplasty: a 20-year follow-up registry study on 3647 implants

Revision total hip arthroplasty (rTHA) often requires femoral stem revision due to aseptic loosening, instability, or fractures. Long, tapered conical stems are preferred for stability and bone loss management. Recent design changes, like increased conicity angles, aim to enhance fixation and reduce subsidence. Monoblock and modular stems offer distinct pros and cons, but their long-term outcomes remain debated. This study evaluates the long-term survival of monoblock versus modular conical stems, with a focus on conicity angles (2° vs. 3°), using 20 years of registry data. A retrospective review was conducted using the Emilia Romagna Registry of Orthopedic Prosthetic Implants (RIPO) from 2000 to 2021. A total of 3,647 non-cemented conical stems used in rTHA were analyzed: 32.4% monoblock and 67.6% modular. Kaplan–Meier survival analysis assessed implant longevity, stratified by stem design and conicity angle. Use of modular stems increased from 24% to over 83% during the study period. Overall failure rate was 6.3–5.1% for monoblock stems (mainly due to aseptic loosening) and 6.9% for modular stems (primarily due to instability). Monoblock stems had superior 20-year survival (93.7%) compared to modular (86.8%, p = 0.009). Among modular stems, those with 2° conicity had significantly better 15-year survival (91.9%) than 3° designs (88.0%, p = 0.001). No significant difference was observed between conicity angles in monoblock stems. Monoblock stems provide better long-term survival in rTHA. Modular designs, while offering intraoperative flexibility, carry higher revision risk, especially with greater conicity. Stem selection should balance design features with patient needs and surgical expertise.

Authors

Institutions

Publication Details

Journal
European Journal of Orthopaedic Surgery & Traumatology
Published
2025-12-08
DOI
https://doi.org/10.1007/s00590-025-04616-7
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monoblock or modular? Impact of stem design and conicity angle on long-term implant survival in revision total hip arthroplasty: a 20-year follow-up registry study on 3647 implants

Claudio D’Agostino, Barbara Bordini, Massimo Morandi, Matteo Brunello et al.
European Journal of Orthopaedic Surgery & Traumatology
Orthopaedic implants and arthroplasty
article

Monoblock or modular? Impact of stem design and conicity angle on long-term implant survival in revision total hip arthroplasty: a 20-year follow-up registry study on 3647 implants

Claudio D’Agostino, Barbara Bordini, Massimo Morandi, Matteo Brunello, Cesare Faldini, Alberto Di Martino, Chiara Di Censo
article en

Abstract

Revision total hip arthroplasty (rTHA) often requires femoral stem revision due to aseptic loosening, instability, or fractures. Long, tapered conical stems are preferred for stability and bone loss management. Recent design changes, like increased conicity angles, aim to enhance fixation and reduce subsidence. Monoblock and modular stems offer distinct pros and cons, but their long-term outcomes remain debated. This study evaluates the long-term survival of monoblock versus modular conical stems, with a focus on conicity angles (2° vs. 3°), using 20 years of registry data. A retrospective review was conducted using the Emilia Romagna Registry of Orthopedic Prosthetic Implants (RIPO) from 2000 to 2021. A total of 3,647 non-cemented conical stems used in rTHA were analyzed: 32.4% monoblock and 67.6% modular. Kaplan–Meier survival analysis assessed implant longevity, stratified by stem design and conicity angle. Use of modular stems increased from 24% to over 83% during the study period. Overall failure rate was 6.3–5.1% for monoblock stems (mainly due to aseptic loosening) and 6.9% for modular stems (primarily due to instability). Monoblock stems had superior 20-year survival (93.7%) compared to modular (86.8%, p = 0.009). Among modular stems, those with 2° conicity had significantly better 15-year survival (91.9%) than 3° designs (88.0%, p = 0.001). No significant difference was observed between conicity angles in monoblock stems. Monoblock stems provide better long-term survival in rTHA. Modular designs, while offering intraoperative flexibility, carry higher revision risk, especially with greater conicity. Stem selection should balance design features with patient needs and surgical expertise.

European Journal of Orthopaedic Surgery & TraumatologyVol. 36(1)
Istituto Ortopedico Rizzoli (IT), University of Bologna (IT)
Università di Bologna
Openalex Percentile: Top 42%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.