Standardized Gait Analysis Using 3D Markerless Motion Capture: A Proposed Procedure and Reliability Investigation in Healthy Young Adults

Background: Quantitative gait analysis is essential in both clinical and research contexts; however, traditional marker-based motion capture systems are costly and burdensome. Advances in three-dimensional markerless motion capture (3D-MMC) offer more accessible alternatives; however, they lack standardized protocols. Objectives: The present study aimed to establish a standardized protocol and procedures for 3D MMC-based gait analysis using OpenCap and to quantify the reliability and within-session precision of key spatiotemporal gait parameters. Methods: Fifty healthy university students (mean age = 22.15 ± 2.12 years) completed walking trials along a 10 m walkway under single-task (ST) and five dual-task (DT) conditions of varying cognitive complexity. Gait data were collected using a two-camera OpenCap 3D-MMC system, with standardized calibration, lighting, clothing, and trial segmentation. Spatiotemporal parameters were extracted, and within-session relative reliability was quantified using two-way mixed-effects intraclass correlation coefficients, and absolute reliability was quantified using general linear model–derived within-subject error (standard error of measurement, SEM) and minimal detectable change (MDC). Repeated-measures ANOVA with Bonferroni corrections were used to examine condition-related differences. Results: Of 500 trials, 491 (98.2%) were successfully processed. Within-subject test–retest reliability ranged from moderate to excellent for all variables, with gait speed, stride length, and cadence showing the highest ICCs and smallest SEM and MDC values, and step width and double support exhibiting larger measurement error. Conclusions: This study establishes a standardized 3D-MMC protocol for gait analysis using OpenCap and demonstrates good to excellent within-session relative and absolute reliability for most spatiotemporal gait parameters in healthy young adults. Dual-task walking is used here to illustrate how trial-averaged OpenCap measurements and their SEM/MDC can be used to determine which condition-related changes in gait exceed measurement error.

Authors

Institutions

Publication Details

Journal
Biomechanics
Published
2025-12-07
DOI
https://doi.org/10.3390/biomechanics5040105
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Standardized Gait Analysis Using 3D Markerless Motion Capture: A Proposed Procedure and Reliability Investigation in Healthy Young Adults

Antonio Vitarelli, Alezandria K. Turner, Christopher J. Keating, Sarah Jane Viljoen
Biomechanics
Balance, Gait, and Falls Prevention
article

Standardized Gait Analysis Using 3D Markerless Motion Capture: A Proposed Procedure and Reliability Investigation in Healthy Young Adults

Antonio Vitarelli, Alezandria K. Turner, Christopher J. Keating, Sarah Jane Viljoen
article en

Abstract

Background: Quantitative gait analysis is essential in both clinical and research contexts; however, traditional marker-based motion capture systems are costly and burdensome. Advances in three-dimensional markerless motion capture (3D-MMC) offer more accessible alternatives; however, they lack standardized protocols. Objectives: The present study aimed to establish a standardized protocol and procedures for 3D MMC-based gait analysis using OpenCap and to quantify the reliability and within-session precision of key spatiotemporal gait parameters. Methods: Fifty healthy university students (mean age = 22.15 ± 2.12 years) completed walking trials along a 10 m walkway under single-task (ST) and five dual-task (DT) conditions of varying cognitive complexity. Gait data were collected using a two-camera OpenCap 3D-MMC system, with standardized calibration, lighting, clothing, and trial segmentation. Spatiotemporal parameters were extracted, and within-session relative reliability was quantified using two-way mixed-effects intraclass correlation coefficients, and absolute reliability was quantified using general linear model–derived within-subject error (standard error of measurement, SEM) and minimal detectable change (MDC). Repeated-measures ANOVA with Bonferroni corrections were used to examine condition-related differences. Results: Of 500 trials, 491 (98.2%) were successfully processed. Within-subject test–retest reliability ranged from moderate to excellent for all variables, with gait speed, stride length, and cadence showing the highest ICCs and smallest SEM and MDC values, and step width and double support exhibiting larger measurement error. Conclusions: This study establishes a standardized 3D-MMC protocol for gait analysis using OpenCap and demonstrates good to excellent within-session relative and absolute reliability for most spatiotemporal gait parameters in healthy young adults. Dual-task walking is used here to illustrate how trial-averaged OpenCap measurements and their SEM/MDC can be used to determine which condition-related changes in gait exceed measurement error.

BiomechanicsVol. 5(4)
University of Verona (IT), San Raffaele University of Rome (IT), Universidad Católica de Murcia (ES)
Openalex Percentile: Top 43%
Balance, Gait, and Falls Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.