Radiation shielding for nuclear medicine using advanced dy-doped nanocomposites

Effective radiation shielding is critical for medical and nuclear safety, but conventional lead-based materials are toxic and heavy. However, a high-performance, non-toxic alternative with optimized composition for mixed-field radiation remains an unmet need. Here establish a new class of lightweight, lead-free shields using dysprosium-doped Mn–Cu ferrite nanocomposites. The selected nanocomposites with varying Dy concentrations (0 to15 mole) and evaluated their gamma-ray (0.015 to 1 MeV) and fast neutron shielding performance. Key parameters, including mass attenuation coefficient, half-value layer and fast neutron removal cross-section (Σ R ), were simulated using the Geant4 toolkit. Shielding efficacy increased systematically with Dy content. The 15% Dy-doped sample (MCDFO15) demonstrated unprecedented performance, requiring up to 25% less thickness than the undoped composite at 200 keV for equivalent gamma attenuation. MCDFO15 exhibited a superior fast neutron removal cross-section (Σ R ≈ 0.062 cm⁻¹ vs. 0.054 cm⁻¹ for MCFO) and a higher neutron absorption ratio. This enhancement is directly attributable to the increased effective atomic number and electron density from Dy doping. Dy doping transforms the intrinsic shielding properties of ferrite nanocomposites, establishing a highly effective strategy for radiation protection. This work paves the way for the development of tunable, non-toxic shields for advanced diagnostic and nuclear applications.

Authors

Publication Details

Journal
Nano Trends
Published
2025-12-08
DOI
https://doi.org/10.1016/j.nwnano.2025.100171
Primary Topic
Radiation Shielding Materials Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Radiation shielding for nuclear medicine using advanced dy-doped nanocomposites

Omid Akhavan, M. Eshghi, Mohammadreza Alipoor
Nano Trends
Radiation Shielding Materials Analysis
article

Radiation shielding for nuclear medicine using advanced dy-doped nanocomposites

Omid Akhavan, M. Eshghi, Mohammadreza Alipoor
article en

Abstract

Effective radiation shielding is critical for medical and nuclear safety, but conventional lead-based materials are toxic and heavy. However, a high-performance, non-toxic alternative with optimized composition for mixed-field radiation remains an unmet need. Here establish a new class of lightweight, lead-free shields using dysprosium-doped Mn–Cu ferrite nanocomposites. The selected nanocomposites with varying Dy concentrations (0 to15 mole) and evaluated their gamma-ray (0.015 to 1 MeV) and fast neutron shielding performance. Key parameters, including mass attenuation coefficient, half-value layer and fast neutron removal cross-section (Σ R ), were simulated using the Geant4 toolkit. Shielding efficacy increased systematically with Dy content. The 15% Dy-doped sample (MCDFO15) demonstrated unprecedented performance, requiring up to 25% less thickness than the undoped composite at 200 keV for equivalent gamma attenuation. MCDFO15 exhibited a superior fast neutron removal cross-section (Σ R ≈ 0.062 cm⁻¹ vs. 0.054 cm⁻¹ for MCFO) and a higher neutron absorption ratio. This enhancement is directly attributable to the increased effective atomic number and electron density from Dy doping. Dy doping transforms the intrinsic shielding properties of ferrite nanocomposites, establishing a highly effective strategy for radiation protection. This work paves the way for the development of tunable, non-toxic shields for advanced diagnostic and nuclear applications.

Nano TrendsVol. 13
Openalex Percentile: Top 68%
Radiation Shielding Materials Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.