Estimating the optical properties of corneal tissue from the OCT speckle

Estimating the scattering coefficient <i>μ</i> <sub><i>s</i></sub> and scattering anisotropy factor <i>g</i> of the corneal tissue is currently limited to methods utilizing double integrating spheres or spectroscopic techniques, prohibiting such corneal tissue evaluation from being performed in a clinical setting. This paper presents a new concept of statistical matching between a given corneal optical coherence tomography (OCT) scan and a set of multi-reference phantom OCT B-scans, suitably simulated using the Monte Carlo method. The statistical matching that exploits the information present in the speckle includes an ensemble of distance measures. Using a set of OCT scans from 11 porcine eyeballs, for which epithelium was removed, it is demonstrated that the proposed statistical matching approach leads to a precise estimation of the optical properties of corneal stroma. The group mean of the scattering coefficient and the scattering anisotropy factor for the porcine stroma were <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub> <mml:mrow><mml:mover><mml:mi>μ</mml:mi> <mml:mo>¯</mml:mo></mml:mover> </mml:mrow> <mml:mi>s</mml:mi></mml:msub> <mml:mo>=</mml:mo> <mml:mn>0.146</mml:mn> <mml:mo>±</mml:mo> <mml:mn>0.020</mml:mn></mml:math> mm<sup>-1</sup> and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow><mml:mover><mml:mi>g</mml:mi> <mml:mo>¯</mml:mo></mml:mover> </mml:mrow> <mml:mo>=</mml:mo> <mml:mn>0.893</mml:mn> <mml:mo>±</mml:mo> <mml:mn>0.021</mml:mn></mml:math> , respectively. These estimates match previously reported values established with other methods. The proposed approach of utilizing information present in the speckle can be readily extended to in vivo OCT imaging of human corneal tissue.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2025-12-08
DOI
https://doi.org/10.1364/boe.579879
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Estimating the optical properties of corneal tissue from the OCT speckle

Maria Miażdżyk, D. Robert Iskander, Alejandra Consejo
Biomedical Optics Express
Optical Coherence Tomography Applications
article

Estimating the optical properties of corneal tissue from the OCT speckle

Maria Miażdżyk, D. Robert Iskander, Alejandra Consejo
article en

Abstract

Estimating the scattering coefficient <i>μ</i> <sub><i>s</i></sub> and scattering anisotropy factor <i>g</i> of the corneal tissue is currently limited to methods utilizing double integrating spheres or spectroscopic techniques, prohibiting such corneal tissue evaluation from being performed in a clinical setting. This paper presents a new concept of statistical matching between a given corneal optical coherence tomography (OCT) scan and a set of multi-reference phantom OCT B-scans, suitably simulated using the Monte Carlo method. The statistical matching that exploits the information present in the speckle includes an ensemble of distance measures. Using a set of OCT scans from 11 porcine eyeballs, for which epithelium was removed, it is demonstrated that the proposed statistical matching approach leads to a precise estimation of the optical properties of corneal stroma. The group mean of the scattering coefficient and the scattering anisotropy factor for the porcine stroma were <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:msub> <mml:mrow><mml:mover><mml:mi>μ</mml:mi> <mml:mo>¯</mml:mo></mml:mover> </mml:mrow> <mml:mi>s</mml:mi></mml:msub> <mml:mo>=</mml:mo> <mml:mn>0.146</mml:mn> <mml:mo>±</mml:mo> <mml:mn>0.020</mml:mn></mml:math> mm<sup>-1</sup> and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow><mml:mover><mml:mi>g</mml:mi> <mml:mo>¯</mml:mo></mml:mover> </mml:mrow> <mml:mo>=</mml:mo> <mml:mn>0.893</mml:mn> <mml:mo>±</mml:mo> <mml:mn>0.021</mml:mn></mml:math> , respectively. These estimates match previously reported values established with other methods. The proposed approach of utilizing information present in the speckle can be readily extended to in vivo OCT imaging of human corneal tissue.

Biomedical Optics ExpressVol. 17(2)
Wrocław University of Science and Technology (PL), Universidad de Zaragoza (ES), AGH University of Krakow (PL)
Openalex Percentile: Top 62%
Optical Coherence Tomography Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.