Aeroacoustic impact of heat exchanger installation in an industrial engine cooling module

Engine cooling fan noise becomes even more difficult to predict when considering the presence of the heat exchanger upstream. This paper investigates the impact of different heat exchanger installations on the noise sources of an industrial engine cooling fan using high-fidelity lattice-Boltzmann simulations. The heat exchanger is simulated using an equivalent porous medium upstream of the fan. Four configurations are analyzed at free discharge: full cooling module (i) without and (ii) with a gap between the heat exchanger and its casing, (iii) Fan+Frame, and (iv) Fan. For the sake of comparison, configurations (iii) and (iv) are simulated by imposing a pressure difference that matches the one across the heat exchanger, to ensure that the same operating point is maintained. Results show negligible differences in the overall aerodynamic performance since the same average pressure rise is achieved. The presence of the porous medium affects the spatial distribution of the pressure field upstream of the fan, thus causing a higher tonal content compared to the configurations (iii) and (iv). Further subharmonic humps are caused by the interaction of the blades with vortex structures generated by flow separation at the tip and the casing’s support structures. The presence of a geometry transition from square to round in the casing causes inflow distortions, increasing low-frequency broadband noise. • Assessment of heat-exchanger installation effects on fan aeroacoustics using high-fidelity lattice-Boltzmann simulations. • Comparison of four installations to isolate heat-exchanger core, frame, and gaps sealing effects on noise generation. • The porous medium modeling of the heat exchanger core alters inflow uniformity and enhances tonal noise. • Small casing-heat exchanger gaps cause measurable changes in recirculation and acoustic signatures. • Casing-induced inflow distortions are the key drivers of subharmonic humps and low-frequency broadband noise.

Authors

Publication Details

Journal
Applied Acoustics
Published
2025-12-07
DOI
https://doi.org/10.1016/j.apacoust.2025.111175
Primary Topic
Aerodynamics and Acoustics in Jet Flows
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Aeroacoustic impact of heat exchanger installation in an industrial engine cooling module

Renzo Arina, Francesco Avallone, Stéphane Moreau, Francesco Bellelli
Applied Acoustics
Aerodynamics and Acoustics in Jet Flows
article

Aeroacoustic impact of heat exchanger installation in an industrial engine cooling module

Renzo Arina, Francesco Avallone, Stéphane Moreau, Francesco Bellelli
article en

Abstract

Engine cooling fan noise becomes even more difficult to predict when considering the presence of the heat exchanger upstream. This paper investigates the impact of different heat exchanger installations on the noise sources of an industrial engine cooling fan using high-fidelity lattice-Boltzmann simulations. The heat exchanger is simulated using an equivalent porous medium upstream of the fan. Four configurations are analyzed at free discharge: full cooling module (i) without and (ii) with a gap between the heat exchanger and its casing, (iii) Fan+Frame, and (iv) Fan. For the sake of comparison, configurations (iii) and (iv) are simulated by imposing a pressure difference that matches the one across the heat exchanger, to ensure that the same operating point is maintained. Results show negligible differences in the overall aerodynamic performance since the same average pressure rise is achieved. The presence of the porous medium affects the spatial distribution of the pressure field upstream of the fan, thus causing a higher tonal content compared to the configurations (iii) and (iv). Further subharmonic humps are caused by the interaction of the blades with vortex structures generated by flow separation at the tip and the casing’s support structures. The presence of a geometry transition from square to round in the casing causes inflow distortions, increasing low-frequency broadband noise. • Assessment of heat-exchanger installation effects on fan aeroacoustics using high-fidelity lattice-Boltzmann simulations. • Comparison of four installations to isolate heat-exchanger core, frame, and gaps sealing effects on noise generation. • The porous medium modeling of the heat exchanger core alters inflow uniformity and enhances tonal noise. • Small casing-heat exchanger gaps cause measurable changes in recirculation and acoustic signatures. • Casing-induced inflow distortions are the key drivers of subharmonic humps and low-frequency broadband noise.

Applied AcousticsVol. 245
Openalex Percentile: Top 50%
Aerodynamics and Acoustics in Jet Flows
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Aeroacoustic impact of heat exchanger installation in an industrial engine cooling module — Renzo Arina, Francesco Avallone, et al. · Applied Acoustics (2025) | TGRS Research Map | TGRS