Role of Wall Compliance and Cushioning in the Fluid-Structure Interaction Study of a High-Flow Artery

<i>Purpose:</i> Fluid-structure interaction (FSI) techniques have become widely accepted numerical tools for analysing transient flows through compliant channels and tubes. However, FSI remains computationally demanding and requires assumptions about certain parameters that are often difficult to determine, particularly in biomedical applications. This study aimed to demonstrate the importance of key decisions required to conduct FSI simulations. <i>Methods:</i> Appropriate material properties were selected and parameters that define the magnitude of external reactions and cushioning effects (which are usually unknown but can be discovered through reverse engineering were set). Using a simplified model of an elastic straight tube, which represents a high-flow artery, reduced the influence of shape and associated mesh imperfections on the results. <i>Results:</i> Wall deformation, von Mises stress, wall shear stress and the pressure drop along the tube were analysed. Verification with various mesh densities for the compliant wall demonstrated that mesh fidelity significantly affects von Mises stress and computation time on a standard PC but has a negligible effect on wall deformation, wall shear stress and pressure drop. <i>Conclusions:</i> Varying wall stiffness and foundation stiffness affected the resulting compliance and all monitored parameters. Additionally, applying different mass and stiffness coefficients to define Rayleigh damping identified a safe range of applicability of this type of damping, however, experimental validation is necessary to determine appropriate values for specific applications and avoid overdamping. Finally, the results were discussed in the context of other FSI research and relevant in vivo and in vitro blood flow studies.

Authors

Institutions

Publication Details

Journal
Acta of Bioengineering and Biomechanics
Published
2025-11-05
DOI
https://doi.org/10.37190/abb/210576
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Role of Wall Compliance and Cushioning in the Fluid-Structure Interaction Study of a High-Flow Artery

Daniel Jodko
Acta of Bioengineering and Biomechanics
Coronary Interventions and Diagnostics
article

Role of Wall Compliance and Cushioning in the Fluid-Structure Interaction Study of a High-Flow Artery

Daniel Jodko
article en

Abstract

<i>Purpose:</i> Fluid-structure interaction (FSI) techniques have become widely accepted numerical tools for analysing transient flows through compliant channels and tubes. However, FSI remains computationally demanding and requires assumptions about certain parameters that are often difficult to determine, particularly in biomedical applications. This study aimed to demonstrate the importance of key decisions required to conduct FSI simulations. <i>Methods:</i> Appropriate material properties were selected and parameters that define the magnitude of external reactions and cushioning effects (which are usually unknown but can be discovered through reverse engineering were set). Using a simplified model of an elastic straight tube, which represents a high-flow artery, reduced the influence of shape and associated mesh imperfections on the results. <i>Results:</i> Wall deformation, von Mises stress, wall shear stress and the pressure drop along the tube were analysed. Verification with various mesh densities for the compliant wall demonstrated that mesh fidelity significantly affects von Mises stress and computation time on a standard PC but has a negligible effect on wall deformation, wall shear stress and pressure drop. <i>Conclusions:</i> Varying wall stiffness and foundation stiffness affected the resulting compliance and all monitored parameters. Additionally, applying different mass and stiffness coefficients to define Rayleigh damping identified a safe range of applicability of this type of damping, however, experimental validation is necessary to determine appropriate values for specific applications and avoid overdamping. Finally, the results were discussed in the context of other FSI research and relevant in vivo and in vitro blood flow studies.

Acta of Bioengineering and BiomechanicsVol. 27(**3)
Lodz University of Technology (PL)
University of New South Wales, Narodowa Agencja Wymiany Akademickiej
Openalex Percentile: Top 42%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Role of Wall Compliance and Cushioning in the Fluid-Structure Interaction Study of a High-Flow Artery — Daniel Jodko · Acta of Bioengineering and Biomechanics (2025) | TGRS Research Map | TGRS