Comparative image quality evaluation of unenhanced postmortem Photon-Counting CT and Energy-Integrating CT

This study evaluates the image quality of postmortem photon-counting computed tomography (PMPCCT) compared to conventional postmortem energy-integrating computed tomography (PMCT) for a protocol adapted to post-mortem imaging. The focus lies on objective image quality parameters such as noise, signal-to-noise ratio, and contrast-to-noise ratio, supplemented by subjective image quality evaluations. A Chest Phantom N1 and one decedent were scanned using PMCT (Siemens SOMATOM<sup>®</sup> X-Cite; slice thicknesses of 1 mm and 0.5 mm; Br40, Br60) and PMPCCT (Siemens NAEOTOM Alpha.peak<sup>®</sup>; slice thicknesses of 1 mm, 0.4 mm, and 0.2 mm; Br40, Br60). Image quality parameters were computed for regions of interest. In addition, two radiologists conducted subjective image quality evaluations (noise, overall image quality, sharpness, bone details, contour visibility, and artifact formation) using a modified Likert scale. The overall findings were mixed, with PMPCCT potentially demonstrating an advantage over PMCT in terms of SNR and CNR, particularly at moderate slice thicknesses of 1 mm and 0.4 mm. The results obtained from the phantom exhibit in some cases considerable differences compared to those from the decedent, so that model studies can hardly be transferred to reality without scrutiny. PMPCCT outperformed PMCT in subjective assessments of overall image quality, sharpness, and bone detail, particularly with Br40 reconstruction kernels. PMPCCT may demonstrate advantages in objective and subjective image quality, with improvements in soft tissue imaging, sharpness, and bone detail at moderate slice thicknesses. These results may suggest PMPCCTs promising potential in forensic imaging. Further studies are needed to investigate and optimize its utility in postmortem settings.

Authors

Institutions

Publication Details

Journal
Forensic Science Medicine and Pathology
Published
2025-12-06
DOI
https://doi.org/10.1007/s12024-025-01118-0
Citations
1
Primary Topic
Autopsy Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative image quality evaluation of unenhanced postmortem Photon-Counting CT and Energy-Integrating CT

Thomas D. Ruder, Paul Lombardo, Hendrik von Tengg‐Kobligk, Conny Hartmann et al.
1 citations
Forensic Science Medicine and Pathology
Autopsy Techniques and Outcomes
1.36
article

Comparative image quality evaluation of unenhanced postmortem Photon-Counting CT and Energy-Integrating CT

Thomas D. Ruder, Paul Lombardo, Hendrik von Tengg‐Kobligk, Conny Hartmann, Wolf‐Dieter Zech, Peter H. Cossmann, S. Garni, Sarah Heinze, S Kessler, Magda Roidou
article en
1 citations

Abstract

This study evaluates the image quality of postmortem photon-counting computed tomography (PMPCCT) compared to conventional postmortem energy-integrating computed tomography (PMCT) for a protocol adapted to post-mortem imaging. The focus lies on objective image quality parameters such as noise, signal-to-noise ratio, and contrast-to-noise ratio, supplemented by subjective image quality evaluations. A Chest Phantom N1 and one decedent were scanned using PMCT (Siemens SOMATOM<sup>®</sup> X-Cite; slice thicknesses of 1 mm and 0.5 mm; Br40, Br60) and PMPCCT (Siemens NAEOTOM Alpha.peak<sup>®</sup>; slice thicknesses of 1 mm, 0.4 mm, and 0.2 mm; Br40, Br60). Image quality parameters were computed for regions of interest. In addition, two radiologists conducted subjective image quality evaluations (noise, overall image quality, sharpness, bone details, contour visibility, and artifact formation) using a modified Likert scale. The overall findings were mixed, with PMPCCT potentially demonstrating an advantage over PMCT in terms of SNR and CNR, particularly at moderate slice thicknesses of 1 mm and 0.4 mm. The results obtained from the phantom exhibit in some cases considerable differences compared to those from the decedent, so that model studies can hardly be transferred to reality without scrutiny. PMPCCT outperformed PMCT in subjective assessments of overall image quality, sharpness, and bone detail, particularly with Br40 reconstruction kernels. PMPCCT may demonstrate advantages in objective and subjective image quality, with improvements in soft tissue imaging, sharpness, and bone detail at moderate slice thicknesses. These results may suggest PMPCCTs promising potential in forensic imaging. Further studies are needed to investigate and optimize its utility in postmortem settings.

Forensic Science Medicine and Pathology
University of Bern (CH), Medical University of Graz (AT), University Hospital of Bern (CH), Planconsult (Switzerland) (CH)
University of Bern
Openalex Percentile: Top 14%
Autopsy Techniques and Outcomes
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.