On the measurement of the junction potential between two aqueous single electrolyte solutions

• Experimental method of measurements of junction potentials is proposed. • The experimental set-up is presented. • Its applicability and limitations is discussed. • Its coherence with the previous research is demonstrated. A method to measure the junction potential between two aqueous electrolyte solutions is proposed. The experimental set up requires a solid-state ion selective electrode and two identical single junction reference electrodes, each containing one of the solutions whose junction potential is to be measured. The two reference electrodes and the ion selective electrode are immersed in an aqueous electrolyte solution, containing the ion to which the ISE responds. In principle, if there is no interference in the voltage response of the ISE from other ions present in the sample solution, the application of the method is independent of the type of ion-selective electrode used.

Authors

Institutions

Publication Details

Journal
Chemical Thermodynamics and Thermal Analysis
Published
2025-12-06
DOI
https://doi.org/10.1016/j.ctta.2025.100252
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the measurement of the junction potential between two aqueous single electrolyte solutions

Juan H. Vera, Grażyna Wilczek-Vera
Chemical Thermodynamics and Thermal Analysis
Analytical Chemistry and Sensors
article

On the measurement of the junction potential between two aqueous single electrolyte solutions

Juan H. Vera, Grażyna Wilczek-Vera
article en

Abstract

• Experimental method of measurements of junction potentials is proposed. • The experimental set-up is presented. • Its applicability and limitations is discussed. • Its coherence with the previous research is demonstrated. A method to measure the junction potential between two aqueous electrolyte solutions is proposed. The experimental set up requires a solid-state ion selective electrode and two identical single junction reference electrodes, each containing one of the solutions whose junction potential is to be measured. The two reference electrodes and the ion selective electrode are immersed in an aqueous electrolyte solution, containing the ion to which the ISE responds. In principle, if there is no interference in the voltage response of the ISE from other ions present in the sample solution, the application of the method is independent of the type of ion-selective electrode used.

Chemical Thermodynamics and Thermal AnalysisVol. 21
McGill University (CA)
Openalex Percentile: Top 55%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.