Fabrication of a Master Mold for Microneedles with a Micron-sized Air-vent Hole

Microneedles (MNs) are a novel drug-delivery system that can penetrate the skin barrier in a minimally invasive way to deliver drugs. Because they are less painful than injections and easy to use, they are seeing expanding applications in the cosmetic and pharmaceutical fields. Conventional MN fabrication involves creating a master mold and then producing MNs in that mold. The primary methods for fabricating the master mold include micro-electromechanical system processes, metal machining, and 3D printing. However, the major weakness of master molds produced by these methods is that air can become trapped inside the mold while casting the very viscous polymer used to make MNs. As a result, the MN tips may not form completely. In MN array fabrication, this can reduce the reliability of the MN structures. This study proposes a solution to air entrapment that involves forming a microscale air-vent hole (AVH) at the tip of the master mold. The AVH allows air to escape, but prevents the viscous fluid from leaking out during the curing process. Because conventional metal machining or 3D printing methods have resolution limitations, silicon micromachining was used to create the AVH-equipped master mold. The side length of the fabricated AVH ranged from 1.4 to 7.0 µm. Using this mold, we successfully fabricated 375 µm-high gelatin MNs with sharp tips. Furthermore, by controlling the volume of gelatin applied, thin-walled hollow pyramidal MNs with 23 µm thick walls and an internal cavity volume of 0.027 µL were also fabricated. Since the AVH-equipped master mold allows fabrication of both water-soluble and water-insoluble MNs, it could serve as a next-generation high-efficiency drug delivery system for applications in cosmeceutical and biomedical fields.

Authors

Institutions

Publication Details

Journal
Journal of Visualized Experiments
Published
2025-12-05
DOI
https://doi.org/10.3791/69679
Primary Topic
Advancements in Transdermal Drug Delivery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fabrication of a Master Mold for Microneedles with a Micron-sized Air-vent Hole

Suhkneung Pyo, Sangyeon Han, Ok Chan Jeong, Hyerin Ahn et al.
Journal of Visualized Experiments
Advancements in Transdermal Drug Delivery
article

Fabrication of a Master Mold for Microneedles with a Micron-sized Air-vent Hole

Suhkneung Pyo, Sangyeon Han, Ok Chan Jeong, Hyerin Ahn, Jaehyeong Kim
article en

Abstract

Microneedles (MNs) are a novel drug-delivery system that can penetrate the skin barrier in a minimally invasive way to deliver drugs. Because they are less painful than injections and easy to use, they are seeing expanding applications in the cosmetic and pharmaceutical fields. Conventional MN fabrication involves creating a master mold and then producing MNs in that mold. The primary methods for fabricating the master mold include micro-electromechanical system processes, metal machining, and 3D printing. However, the major weakness of master molds produced by these methods is that air can become trapped inside the mold while casting the very viscous polymer used to make MNs. As a result, the MN tips may not form completely. In MN array fabrication, this can reduce the reliability of the MN structures. This study proposes a solution to air entrapment that involves forming a microscale air-vent hole (AVH) at the tip of the master mold. The AVH allows air to escape, but prevents the viscous fluid from leaking out during the curing process. Because conventional metal machining or 3D printing methods have resolution limitations, silicon micromachining was used to create the AVH-equipped master mold. The side length of the fabricated AVH ranged from 1.4 to 7.0 µm. Using this mold, we successfully fabricated 375 µm-high gelatin MNs with sharp tips. Furthermore, by controlling the volume of gelatin applied, thin-walled hollow pyramidal MNs with 23 µm thick walls and an internal cavity volume of 0.027 µL were also fabricated. Since the AVH-equipped master mold allows fabrication of both water-soluble and water-insoluble MNs, it could serve as a next-generation high-efficiency drug delivery system for applications in cosmeceutical and biomedical fields.

Journal of Visualized Experiments(226)
Inje University (KR)
Openalex Percentile: Top 68%
Advancements in Transdermal Drug Delivery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fabrication of a Master Mold for Microneedles with a Micron-sized Air-vent Hole — Suhkneung Pyo, Sangyeon Han, et al. · Journal of Visualized Experiments (2025) | TGRS Research Map | TGRS