Deep Learning-Assisted Cactus-Inspired Osmosis-Enrichment Patch for Biosafety-Isolative Wearable Sweat Metabolism Assessment

Sweat, which contains a rich array of biomarkers, serves as a vital biological fluid for non-invasive biosensing. Wearable sweat sensors have garnered significant interest owing to their portability and capacity for continuous monitoring. However, there are safety concerns regarding the direct contact of sweat sensors with the skin during the detection process. The chemical substances in the sensor patches may cause contamination of the epidermis when in contact with the skin, leading to skin allergic reactions. Sample collection and biosafety isolation are critical issues in wearable sweat detection. To address this, we develop a cactus-inspired biomimetic Janus membrane capable of unidirectionally transporting and concentrating sweat toward a designated detection zone. Through unidirectional transport from the hydrophobic layer to the hydrophilic layer of the Janus membrane, sweat droplets are enriched at the designated detection point of the conical hydrophilic pattern via Laplace pressure. The bionic osmosis-enrichment sensing patch effectively inhibits direct contact between indicators and skin, eliminating potential epidermal contamination. This achieved the effect of in situ perspiration collection under the premise of biosafety isolation. To rapidly and accurately analyze sweat biomarkers, we employ a deep learning (DL)-assisted fluorescence sensor for efficient and precise detection of biomarker concentrations. A dataset of 4500 fluorescence images are constructed and used to evaluate two DL and seven machine learning (ML) algorithms. The convolutional neural network (CNN) model could easily and accurately classify and quantitatively analyze the total concentration of the amino acid mixture, Ca<sup>2+</sup> and Cl<sup>-</sup>, with 100% classification accuracy. The consistency between the detection results of actual sweat by the DL-assisted fluorescence method and fluorescence spectroscopy was 91.4-96.0%. This approach demonstrates high reliability in sweat collection and analysis, offering a practical tool for clinical health monitoring, early disease intervention, and diagnosis.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2025-12-01
DOI
https://doi.org/10.3390/bios15120790
Citations
1
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deep Learning-Assisted Cactus-Inspired Osmosis-Enrichment Patch for Biosafety-Isolative Wearable Sweat Metabolism Assessment

Bingtian Su, Ting Xiao, Pan Dong, Wenyan Yue et al.
1 citations
Biosensors
Advanced Sensor and Energy Harvesting Materials
0.67
article

Deep Learning-Assisted Cactus-Inspired Osmosis-Enrichment Patch for Biosafety-Isolative Wearable Sweat Metabolism Assessment

Bingtian Su, Ting Xiao, Pan Dong, Wenyan Yue, Z.F. Zhang, Jihan Qu, Yonghuan Chen, Jianxin Meng, Yong Yan, Meng Lin, Fengyu Li
article en
1 citations

Abstract

Sweat, which contains a rich array of biomarkers, serves as a vital biological fluid for non-invasive biosensing. Wearable sweat sensors have garnered significant interest owing to their portability and capacity for continuous monitoring. However, there are safety concerns regarding the direct contact of sweat sensors with the skin during the detection process. The chemical substances in the sensor patches may cause contamination of the epidermis when in contact with the skin, leading to skin allergic reactions. Sample collection and biosafety isolation are critical issues in wearable sweat detection. To address this, we develop a cactus-inspired biomimetic Janus membrane capable of unidirectionally transporting and concentrating sweat toward a designated detection zone. Through unidirectional transport from the hydrophobic layer to the hydrophilic layer of the Janus membrane, sweat droplets are enriched at the designated detection point of the conical hydrophilic pattern via Laplace pressure. The bionic osmosis-enrichment sensing patch effectively inhibits direct contact between indicators and skin, eliminating potential epidermal contamination. This achieved the effect of in situ perspiration collection under the premise of biosafety isolation. To rapidly and accurately analyze sweat biomarkers, we employ a deep learning (DL)-assisted fluorescence sensor for efficient and precise detection of biomarker concentrations. A dataset of 4500 fluorescence images are constructed and used to evaluate two DL and seven machine learning (ML) algorithms. The convolutional neural network (CNN) model could easily and accurately classify and quantitatively analyze the total concentration of the amino acid mixture, Ca<sup>2+</sup> and Cl<sup>-</sup>, with 100% classification accuracy. The consistency between the detection results of actual sweat by the DL-assisted fluorescence method and fluorescence spectroscopy was 91.4-96.0%. This approach demonstrates high reliability in sweat collection and analysis, offering a practical tool for clinical health monitoring, early disease intervention, and diagnosis.

BiosensorsVol. 15(12)
Jinan University (CN), Zhengzhou University (CN)
Openalex Percentile: Top 24%
Advanced Sensor and Energy Harvesting Materials
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.