Enhancing the Resolution Utilization for DIC Measurement of Slender Components Using Shear Imaging

Digital image correlation (DIC) is widely used for full-field deformation measurement, yet its spatial resolution is often underutilized when measuring slender components due to their high aspect ratio. To address this limitation, a novel virtual multi-camera DIC method that integrates a conventional dual-camera setup with two Michelson shear devices (MSDs) was proposed. Each MSD splits the image of the slender component along its longitudinal direction, projecting two segments side-by-side onto the same camera sensor. This configuration effectively enhances the resolution utilization of each camera, enabling high-resolution measurement of the entire slender surface without requiring additional cameras. The system is calibrated to establish extrinsic parameters between DIC subsystems, allowing stitching of 3D data from different regions. Experimental validation through translation and bending tests demonstrates that the proposed method achieves accurate full-field morphology and deformation measurements, with sub-pixel level agreement in overlapping regions. This approach offers a practical and cost-effective solution for enhancing DIC performance in constrained measurement environments.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-12-02
DOI
https://doi.org/10.3390/s25237346
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing the Resolution Utilization for DIC Measurement of Slender Components Using Shear Imaging

Zhuoxuan Song, Yinhang Ma, Dong Jiang, Kangjiang Lv
Sensors
Optical measurement and interference techniques
article

Enhancing the Resolution Utilization for DIC Measurement of Slender Components Using Shear Imaging

Zhuoxuan Song, Yinhang Ma, Dong Jiang, Kangjiang Lv
article en

Abstract

Digital image correlation (DIC) is widely used for full-field deformation measurement, yet its spatial resolution is often underutilized when measuring slender components due to their high aspect ratio. To address this limitation, a novel virtual multi-camera DIC method that integrates a conventional dual-camera setup with two Michelson shear devices (MSDs) was proposed. Each MSD splits the image of the slender component along its longitudinal direction, projecting two segments side-by-side onto the same camera sensor. This configuration effectively enhances the resolution utilization of each camera, enabling high-resolution measurement of the entire slender surface without requiring additional cameras. The system is calibrated to establish extrinsic parameters between DIC subsystems, allowing stitching of 3D data from different regions. Experimental validation through translation and bending tests demonstrates that the proposed method achieves accurate full-field morphology and deformation measurements, with sub-pixel level agreement in overlapping regions. This approach offers a practical and cost-effective solution for enhancing DIC performance in constrained measurement environments.

SensorsVol. 25(23)
Nanjing Forestry University (CN)
Openalex Percentile: Top 60%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Enhancing the Resolution Utilization for DIC Measurement of Slender Components Using Shear Imaging — Zhuoxuan Song, Yinhang Ma, et al. · Sensors (2025) | TGRS Research Map | TGRS