Few-Shot and Zero-Shot Learning for MRI Brain Tumor Classification Using CLIP and Vision Transformers

Accurate classification of brain tumors from MRI scans remains challenging due to limited annotated data. This study compares data-efficient paradigms-few-shot learning (FSL) and zero-shot learning (ZSL)-for tumor diagnosis using deep learning and vision-language models. A Prototypical Network (ProtoNet) with CNN, ResNet-18, and vision transformer backbones was evaluated under 1000 randomly sampled five-shot, four-way episodes (mean ± SD). The ResNet-18 ProtoNet achieved 85% ± 8% accuracy (F1 = 0.85), surpassing a fine-tuned ResNet-50 baseline (42% ± 12%) and the CLIP (ZSL) model (30% ± 10%). A visual-only ZSL baseline without text guidance achieved 54% ± 11%. These results highlight that metric-based FSL offers 43% absolute improvement over standard fine-tuning and establishes a robust benchmark for data-efficient MRI classification under severe label constraints.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-12-02
DOI
https://doi.org/10.3390/s25237341
Citations
1
Primary Topic
Brain Tumor Detection and Classification
Type
article
Field-Weighted Citation Impact
0.84
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Few-Shot and Zero-Shot Learning for MRI Brain Tumor Classification Using CLIP and Vision Transformers

Saurabh Singh, Aparna Das
1 citations
Sensors
Brain Tumor Detection and Classification
0.84
article

Few-Shot and Zero-Shot Learning for MRI Brain Tumor Classification Using CLIP and Vision Transformers

Saurabh Singh, Aparna Das
article en
1 citations

Abstract

Accurate classification of brain tumors from MRI scans remains challenging due to limited annotated data. This study compares data-efficient paradigms-few-shot learning (FSL) and zero-shot learning (ZSL)-for tumor diagnosis using deep learning and vision-language models. A Prototypical Network (ProtoNet) with CNN, ResNet-18, and vision transformer backbones was evaluated under 1000 randomly sampled five-shot, four-way episodes (mean ± SD). The ResNet-18 ProtoNet achieved 85% ± 8% accuracy (F1 = 0.85), surpassing a fine-tuned ResNet-50 baseline (42% ± 12%) and the CLIP (ZSL) model (30% ± 10%). A visual-only ZSL baseline without text guidance achieved 54% ± 11%. These results highlight that metric-based FSL offers 43% absolute improvement over standard fine-tuning and establishes a robust benchmark for data-efficient MRI classification under severe label constraints.

SensorsVol. 25(23)
Woosong University (KR)
Openalex Percentile: Top 19%
Brain Tumor Detection and Classification
0.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.