DNA Aptamer-Modified Glass Nanopores for Intracellular Dopamine Detection with Improved Sensitivity and Stability

Detecting intracellular dopamine is crucial to understanding neurodegenerative diseases. In this article, we proposed a nanopore sensor utilizing DNA aptamer probes to specifically interact with dopamine, enabling detection of intracellular dopamine in a single pheochromocytoma (PC12) cell. Two different aptamers were designed, and one with higher sensitivity and stability was chosen for the current testing. The nanopore sensor demonstrated a detection limit of 0.92 nM and a wide detection range of 1 nM to 100 μM. The sensor had a response time of ∼15 s upon the addition of 1 μM dopamine and was reversible and reusable (>6 days) with salt gradient enhancement. As a demonstration, the sensor was used for detecting dopamine concentration changes in PC12 cells in response to L-DOPA at different concentrations.

Authors

Institutions

Publication Details

Journal
ACS Applied Nano Materials
Published
2025-12-05
DOI
https://doi.org/10.1021/acsanm.5c05065
Primary Topic
Nanopore and Nanochannel Transport Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DNA Aptamer-Modified Glass Nanopores for Intracellular Dopamine Detection with Improved Sensitivity and Stability

Changling Zhang, Songyue Chen, Yu Xie, Hong Chen et al.
ACS Applied Nano Materials
Nanopore and Nanochannel Transport Studies
article

DNA Aptamer-Modified Glass Nanopores for Intracellular Dopamine Detection with Improved Sensitivity and Stability

Changling Zhang, Songyue Chen, Yu Xie, Hong Chen, Yuru You, Daoheng Sun
article en

Abstract

Detecting intracellular dopamine is crucial to understanding neurodegenerative diseases. In this article, we proposed a nanopore sensor utilizing DNA aptamer probes to specifically interact with dopamine, enabling detection of intracellular dopamine in a single pheochromocytoma (PC12) cell. Two different aptamers were designed, and one with higher sensitivity and stability was chosen for the current testing. The nanopore sensor demonstrated a detection limit of 0.92 nM and a wide detection range of 1 nM to 100 μM. The sensor had a response time of ∼15 s upon the addition of 1 μM dopamine and was reversible and reusable (>6 days) with salt gradient enhancement. As a demonstration, the sensor was used for detecting dopamine concentration changes in PC12 cells in response to L-DOPA at different concentrations.

ACS Applied Nano MaterialsVol. 8(50)
Institute of Technology of Cambodia (KH), Xiamen University (CN), Xiamen University of Technology (CN)
Openalex Percentile: Top 62%
Nanopore and Nanochannel Transport Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

DNA Aptamer-Modified Glass Nanopores for Intracellular Dopamine Detection with Improved Sensitivity and Stability — Changling Zhang, Songyue Chen, et al. · ACS Applied Nano Materials (2025) | TGRS Research Map | TGRS