A Review of Robot-Assisted Needle-Insertion Approaches in Corneal Surgeries

Ophthalmic surgery requires micrometer-level precision due to the eye’s delicate anatomy, yet manual limitations and restricted 3D visualization make absolute accuracy challenging, driving interest in robotic and Artificial Intelligence technologies to enhance safety and precision. This is a narrative review of experimental and published studies on PubMed and Open Evidence to review the current advances, challenges, and translational potential of robotic-assisted needle insertion in corneal surgery. Topics include robotic corneal surgery platforms such as the da Vinci and custom microsurgical robots, telemanipulation, intraoperative optical coherence tomography (iOCT), and reinforcement learning applications. Recent advancements in the field have demonstrated enhanced needle insertion precision, tremor elimination, and improved visualization of needle trajectory in corneal procedures, including corneal lacerations, pterygium repairs and penetrating keratoplasties (PKs). Nonetheless, significant limitations in the state of the art persist, particularly concerning the integration of robotic systems into clinical practice in in vivo settings. Our results indicate that current studies are mostly conducted in an ex vivo setting, which introduces inherent biases and reduces the generalizability of findings to clinical practice. Additionally, the majority of these studies involve small sample sizes, limiting statistical power and the ability to draw robust conclusions. Together, these limitations highlight the need for larger, well-designed in vivo studies to validate and expand upon existing findings. This review bridges experimental innovation and clinical application, highlighting strategies to overcome current barriers in robotic corneal surgery.

Authors

Institutions

Publication Details

Journal
Actuators
Published
2025-12-02
DOI
https://doi.org/10.3390/act14120587
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Review of Robot-Assisted Needle-Insertion Approaches in Corneal Surgeries

Andrés C. Ramos, Eliana-Ruobing Zhang, Guillermo Rocha, Amir Hooshiar et al.
Actuators
Soft Robotics and Applications
article

A Review of Robot-Assisted Needle-Insertion Approaches in Corneal Surgeries

Andrés C. Ramos, Eliana-Ruobing Zhang, Guillermo Rocha, Amir Hooshiar, Giacomo Beschi
article en

Abstract

Ophthalmic surgery requires micrometer-level precision due to the eye’s delicate anatomy, yet manual limitations and restricted 3D visualization make absolute accuracy challenging, driving interest in robotic and Artificial Intelligence technologies to enhance safety and precision. This is a narrative review of experimental and published studies on PubMed and Open Evidence to review the current advances, challenges, and translational potential of robotic-assisted needle insertion in corneal surgery. Topics include robotic corneal surgery platforms such as the da Vinci and custom microsurgical robots, telemanipulation, intraoperative optical coherence tomography (iOCT), and reinforcement learning applications. Recent advancements in the field have demonstrated enhanced needle insertion precision, tremor elimination, and improved visualization of needle trajectory in corneal procedures, including corneal lacerations, pterygium repairs and penetrating keratoplasties (PKs). Nonetheless, significant limitations in the state of the art persist, particularly concerning the integration of robotic systems into clinical practice in in vivo settings. Our results indicate that current studies are mostly conducted in an ex vivo setting, which introduces inherent biases and reduces the generalizability of findings to clinical practice. Additionally, the majority of these studies involve small sample sizes, limiting statistical power and the ability to draw robust conclusions. Together, these limitations highlight the need for larger, well-designed in vivo studies to validate and expand upon existing findings. This review bridges experimental innovation and clinical application, highlighting strategies to overcome current barriers in robotic corneal surgery.

ActuatorsVol. 14(12)
McGill University Health Centre (CA), Surgical Specialties (Canada) (CA), McGill University (CA), University of Brescia (IT)
Openalex Percentile: Top 62%
Soft Robotics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.