A Highly Current-Efficient Electrodialytic Membrane Suppressor for Ion Chromatography

We describe a highly current-efficient electrodialytic membrane suppressor (EMS) for ion chromatography. The device features a typical sandwich-like configuration, where a central eluent channel is spatially isolated from two outer regenerant chambers by two cation exchange membranes (CEMs). The CEM is in intimate contact with sulfonated functionalized screens in the eluent and regenerant chambers, with the aim to reduce the resistance. By using a lightly sulfonated screen with suitable low capacity (e.g., in the range of 40-80 μeq/g) in the eluent channel, the EMSs obtained show 100% current efficiency toward common hydroxide eluent. For example, the suppression current at 16.1 mA or 32.2 mA (theoretical current) allows effective suppression to 10 mM or 20 mM KOH eluent at the typical flow rate of 1 mL/min, as indicated by <1 μS/cm of the suppressed background. The suppressor is able to accommodate suppression of hydroxide eluent up to 80 mM KOH.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-12-05
DOI
https://doi.org/10.1021/acs.analchem.5c05050
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Highly Current-Efficient Electrodialytic Membrane Suppressor for Ion Chromatography

Bingcheng Yang, Xiaoting Li, Feifang Zhang, Jie Zhang et al.
Analytical Chemistry
Analytical Chemistry and Chromatography
article

A Highly Current-Efficient Electrodialytic Membrane Suppressor for Ion Chromatography

Bingcheng Yang, Xiaoting Li, Feifang Zhang, Jie Zhang, Weiqing Chen
article en

Abstract

We describe a highly current-efficient electrodialytic membrane suppressor (EMS) for ion chromatography. The device features a typical sandwich-like configuration, where a central eluent channel is spatially isolated from two outer regenerant chambers by two cation exchange membranes (CEMs). The CEM is in intimate contact with sulfonated functionalized screens in the eluent and regenerant chambers, with the aim to reduce the resistance. By using a lightly sulfonated screen with suitable low capacity (e.g., in the range of 40-80 μeq/g) in the eluent channel, the EMSs obtained show 100% current efficiency toward common hydroxide eluent. For example, the suppression current at 16.1 mA or 32.2 mA (theoretical current) allows effective suppression to 10 mM or 20 mM KOH eluent at the typical flow rate of 1 mL/min, as indicated by <1 μS/cm of the suppressed background. The suppressor is able to accommodate suppression of hydroxide eluent up to 80 mM KOH.

Analytical ChemistryVol. 97(49)
East China University of Science and Technology (CN), Frontier Science Foundation (CH)
Openalex Percentile: Top 65%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.