Time resolution studies for the future LHCb Electromagnetic Calorimeter

During Runs 5 and 6 of the Large Hadron Collider (LHC), the LHCb experiment at CERN will operate at a luminosity up to $1.5\times10^{34}\text{cm}^{-2} \text{s}^{-1}$, requiring substantial upgrades to its Electromagnetic Calorimeter (ECAL). Specifically, the upgraded detector will have to withstand high radiation doses and achieve time resolutions of a few tens of picoseconds in order to mitigate pile-up effects. The inner and high-occupancy regions of the future detector — named PicoCal — will utilize a new Spaghetti-Calorimeter (SpaCal) technology composed of scintillating fibres (polystyrene or garnet crystals) in a dense absorber (lead or tungsten). Ongoing investigations are focused on the photodetectors (PMTs) selection and their impact on the overall timing performance. Simulation studies of a lead-polystyrene module with single-sided readout (PMTs coupled only to the downstream side) show that fast PMTs result in worse time resolutions due to the longitudinal showers' fluctuations, which introduce a bias in the timestamps determined by the Constant Fraction Discriminator (CFD) algorithm. This hypothesis was corroborated by observing that a significant improvement in time resolution would be achievable if the positions of the electromagnetic shower barycenters were known. Additionally, a correlation between signal rise time and depth of the electromagnetic showers has been observed. Data from a test beam campaign conducted at the CERN SPS in June 2024 have been analysed to measure the time resolution of a tungsten-polystyrene SpaCal prototype, comparing four PMT models and two fibre types. By exploiting a rise-time-based correction procedure, time resolutions below 20 ps at high energies have been reached, with the fastest PMTs undergoing larger corrections, as expected from simulations.

Authors

Publication Details

Published
2025-12-05
DOI
https://doi.org/10.22323/1.489.0048
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Time resolution studies for the future LHCb Electromagnetic Calorimeter

Alberto Bellavista
Radiation Detection and Scintillator Technologies
article

Time resolution studies for the future LHCb Electromagnetic Calorimeter

Alberto Bellavista
article en

Abstract

During Runs 5 and 6 of the Large Hadron Collider (LHC), the LHCb experiment at CERN will operate at a luminosity up to $1.5\times10^{34}\text{cm}^{-2} \text{s}^{-1}$, requiring substantial upgrades to its Electromagnetic Calorimeter (ECAL). Specifically, the upgraded detector will have to withstand high radiation doses and achieve time resolutions of a few tens of picoseconds in order to mitigate pile-up effects. The inner and high-occupancy regions of the future detector — named PicoCal — will utilize a new Spaghetti-Calorimeter (SpaCal) technology composed of scintillating fibres (polystyrene or garnet crystals) in a dense absorber (lead or tungsten). Ongoing investigations are focused on the photodetectors (PMTs) selection and their impact on the overall timing performance. Simulation studies of a lead-polystyrene module with single-sided readout (PMTs coupled only to the downstream side) show that fast PMTs result in worse time resolutions due to the longitudinal showers' fluctuations, which introduce a bias in the timestamps determined by the Constant Fraction Discriminator (CFD) algorithm. This hypothesis was corroborated by observing that a significant improvement in time resolution would be achievable if the positions of the electromagnetic shower barycenters were known. Additionally, a correlation between signal rise time and depth of the electromagnetic showers has been observed. Data from a test beam campaign conducted at the CERN SPS in June 2024 have been analysed to measure the time resolution of a tungsten-polystyrene SpaCal prototype, comparing four PMT models and two fibre types. By exploiting a rise-time-based correction procedure, time resolutions below 20 ps at high energies have been reached, with the fastest PMTs undergoing larger corrections, as expected from simulations.

European Commission
Openalex Percentile: Top 53%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Time resolution studies for the future LHCb Electromagnetic Calorimeter — Alberto Bellavista · (2025) | TGRS Research Map | TGRS