Pulsed Field Ablation in Patients With Cardiac Implantable Electric Devices: Vigilance Is Warranted

Pulsed field ablation (PFA) for the treatment of atrial fibrillation offers potential safety benefits compared to thermal ablation modalities. However, the high voltage electric pulses required to irreversibly electroporate myocardial cells present a unique clinical challenge in regard to patients with cardiac implantable electronic devices (CIEDs). The strong electric fields of PFA can induce voltages and currents in CIED leads, which may result in electromagnetic interference (EMI) or even permanent damage to the device itself, requiring reset or replacement. Limited evidence exists on PFA procedures in patients with CIEDs. Historically, clinical trials have excluded patients with CIEDs, which leaves evidence from real-world clinical practice to fill this critical evidence gap. This review describes the potential hazards when performing PFA in patients with CIEDs, current real-world evidence in such patients, and recommended workflows to mitigate risk and prioritize patient safety.

Authors

Institutions

Publication Details

Journal
Pacing and Clinical Electrophysiology
Published
2025-12-05
DOI
https://doi.org/10.1111/pace.70097
Citations
1
Primary Topic
Microbial Inactivation Methods
Type
article
Field-Weighted Citation Impact
1.23

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulsed Field Ablation in Patients With Cardiac Implantable Electric Devices: Vigilance Is Warranted

James Kippola, Brendan Koop, E Albrecht, Emily Lecy
1 citations
Pacing and Clinical Electrophysiology
Microbial Inactivation Methods
1.23
article

Pulsed Field Ablation in Patients With Cardiac Implantable Electric Devices: Vigilance Is Warranted

James Kippola, Brendan Koop, E Albrecht, Emily Lecy
article en
1 citations

Abstract

Pulsed field ablation (PFA) for the treatment of atrial fibrillation offers potential safety benefits compared to thermal ablation modalities. However, the high voltage electric pulses required to irreversibly electroporate myocardial cells present a unique clinical challenge in regard to patients with cardiac implantable electronic devices (CIEDs). The strong electric fields of PFA can induce voltages and currents in CIED leads, which may result in electromagnetic interference (EMI) or even permanent damage to the device itself, requiring reset or replacement. Limited evidence exists on PFA procedures in patients with CIEDs. Historically, clinical trials have excluded patients with CIEDs, which leaves evidence from real-world clinical practice to fill this critical evidence gap. This review describes the potential hazards when performing PFA in patients with CIEDs, current real-world evidence in such patients, and recommended workflows to mitigate risk and prioritize patient safety.

Pacing and Clinical ElectrophysiologyVol. 49(1)
Boston Scientific (United States) (US)
Boston Scientific Corporation
Openalex Percentile: Top 16%
Microbial Inactivation Methods
1.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.