Regulatory Gap Versus Performance Reality: Thermal Assessment of a Social Housing Module in the Peruvian Andes

In high-altitude regions of the Global South, social housing programs are essential for mitigating vulnerability to low temperatures, but their standardized designs often fail to meet thermal performance codes. This study evaluates a “Sumaq Wasi” adobe housing module in the Peruvian Andes (Kunturkanki, 4237 m a.s.l.) during the 2023 frost season. We comparatively applied the 2014 and 2022 draft versions of the Peruvian standard EM.110 to assess the building envelope’s thermal transmittance and condensation risk, benchmarking monitored indoor temperatures against adaptive comfort models. The results revealed widespread non-compliance with thermal transmittance limits, especially for the roof and floor, although condensation risk was low. While indoor temperatures failed to meet conventional standards, they aligned with regionally adapted comfort ranges. We conclude that the standardized module design is insufficient for local climatic demands and argue that social housing policies must evolve, balancing regulatory stringency with context-aware bioclimatic design to be effective.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-12-05
DOI
https://doi.org/10.3390/buildings15244401
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Regulatory Gap Versus Performance Reality: Thermal Assessment of a Social Housing Module in the Peruvian Andes

Enrique Mejía-Solis, Víctor Manuel Salas Velásquez, Edwin Roberto Gudiel Rodríguez, Emilio Palomino-Olivera et al.
Buildings
Building Energy and Comfort Optimization
article

Regulatory Gap Versus Performance Reality: Thermal Assessment of a Social Housing Module in the Peruvian Andes

Enrique Mejía-Solis, Víctor Manuel Salas Velásquez, Edwin Roberto Gudiel Rodríguez, Emilio Palomino-Olivera, Miriam Ancco-Peralta
article en

Abstract

In high-altitude regions of the Global South, social housing programs are essential for mitigating vulnerability to low temperatures, but their standardized designs often fail to meet thermal performance codes. This study evaluates a “Sumaq Wasi” adobe housing module in the Peruvian Andes (Kunturkanki, 4237 m a.s.l.) during the 2023 frost season. We comparatively applied the 2014 and 2022 draft versions of the Peruvian standard EM.110 to assess the building envelope’s thermal transmittance and condensation risk, benchmarking monitored indoor temperatures against adaptive comfort models. The results revealed widespread non-compliance with thermal transmittance limits, especially for the roof and floor, although condensation risk was low. While indoor temperatures failed to meet conventional standards, they aligned with regionally adapted comfort ranges. We conclude that the standardized module design is insufficient for local climatic demands and argue that social housing policies must evolve, balancing regulatory stringency with context-aware bioclimatic design to be effective.

BuildingsVol. 15(24)
National University of Saint Anthony the Abbot in Cuzco (PE), Pontificia Universidad Católica del Perú (PE)
Openalex Percentile: Top 59%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.