Reliability of non-invasive blood pressure monitoring in sick very low birth weight preterm infants

BackgroundAccurate blood pressure (BP) measurement is crucial for assessing hemodynamic features in infants with very low birth weight (VLBW). Various methods are available to monitor BP, including both invasive arterial blood pressure (IBP) and non-invasive blood pressure (NIBP). IBP monitoring, although accurate, poses risks due to its invasive approach, while NIBP monitoring, despite being safer, may lack precision.ObjectiveTo evaluate the agreement between IBP and NIBP measurements and assess the reliability of NIBP in diagnosing hypotension among VLBW infants.MethodsThis study was conducted in the neonatal intensive care unit (NICU) of King Fahd Armed Forces Hospital, Jeddah, Saudi Arabia. VLBW infants (n = 40) with IBP measured via an umbilical arterial catheter (UAC) or peripheral arterial line (PAL) were included. Simultaneous NIBP measurements were taken using appropriately sized cuffs.ResultsAcross 3260 paired measurements, NIBP showed a mean bias of -6 ± 10 mmHg compared to IBP, with 95% limits of agreement from -25.6 to 13.6 mmHg. NIBP overestimated systolic, diastolic, and mean arterial pressures (MAP) by 8.9 mmHg, 7.47 mmHg, and 6.76 mmHg, respectively (all <i>p</i> < 0.001). Overall, 58% of pairs exceeded ±15% of invasive MAP. Invasive hypotension prevalence was 4.3% (MAP < gestational age) and 21.7% (MAP <30 mmHg). Receiver operating characteristics analysis showed modest diagnostic accuracy of NIBP (area under the curve = 0.627 and 0.707), with specificity >90% but sensitivity only 26.6%.ConclusionsNIBP overestimates blood pressure, and IBP is the gold standard method for accurate BP assessment in VLBW infants.

Authors

Institutions

Publication Details

Journal
Journal of Neonatal-Perinatal Medicine
Published
2025-12-05
DOI
https://doi.org/10.1177/19345798251405220
Primary Topic
Neonatal Respiratory Health Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability of non-invasive blood pressure monitoring in sick very low birth weight preterm infants

Nisreen Kafi, Mohamed Abdelmawla, Enshrah Radwan, Ahmed M. Dohain et al.
Journal of Neonatal-Perinatal Medicine
Neonatal Respiratory Health Research
article

Reliability of non-invasive blood pressure monitoring in sick very low birth weight preterm infants

Nisreen Kafi, Mohamed Abdelmawla, Enshrah Radwan, Ahmed M. Dohain, Mohamed Abuzaid, Adeeb Khawaji, Ahmed Elkordy, Ahmed Abuelnour, Raniah Aljeaid
article en

Abstract

BackgroundAccurate blood pressure (BP) measurement is crucial for assessing hemodynamic features in infants with very low birth weight (VLBW). Various methods are available to monitor BP, including both invasive arterial blood pressure (IBP) and non-invasive blood pressure (NIBP). IBP monitoring, although accurate, poses risks due to its invasive approach, while NIBP monitoring, despite being safer, may lack precision.ObjectiveTo evaluate the agreement between IBP and NIBP measurements and assess the reliability of NIBP in diagnosing hypotension among VLBW infants.MethodsThis study was conducted in the neonatal intensive care unit (NICU) of King Fahd Armed Forces Hospital, Jeddah, Saudi Arabia. VLBW infants (n = 40) with IBP measured via an umbilical arterial catheter (UAC) or peripheral arterial line (PAL) were included. Simultaneous NIBP measurements were taken using appropriately sized cuffs.ResultsAcross 3260 paired measurements, NIBP showed a mean bias of -6 ± 10 mmHg compared to IBP, with 95% limits of agreement from -25.6 to 13.6 mmHg. NIBP overestimated systolic, diastolic, and mean arterial pressures (MAP) by 8.9 mmHg, 7.47 mmHg, and 6.76 mmHg, respectively (all <i>p</i> < 0.001). Overall, 58% of pairs exceeded ±15% of invasive MAP. Invasive hypotension prevalence was 4.3% (MAP < gestational age) and 21.7% (MAP <30 mmHg). Receiver operating characteristics analysis showed modest diagnostic accuracy of NIBP (area under the curve = 0.627 and 0.707), with specificity >90% but sensitivity only 26.6%.ConclusionsNIBP overestimates blood pressure, and IBP is the gold standard method for accurate BP assessment in VLBW infants.

Journal of Neonatal-Perinatal Medicine
Manitoba Health (CA), Cairo University (EG), King Fahd Armed Forces Hospital (SA), University of Manitoba (CA)
Openalex Percentile: Top 43%
Neonatal Respiratory Health Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.