Development of Low-Flow High-Resolution Desorption Electrospray Ionization Mass Spectrometry Imaging

Desorption electrospray ionization mass spectrometry (DESI-MS) imaging is a well-established technique for molecular analysis of biological samples, although its spatial resolution has been limited when compared to other MS imaging techniques. Here, we describe the development and optimization of a low-flow DESI-MS method that allows for sub-10 μm spatial resolution tissue imaging using a commercial DESI sprayer. Key technical modifications that enabled low-flow high-resolution DESI-MS imaging include reduced solvent flow rates below 350 nL/min, increased solvent pump back-pressure for spray stability, and optimized sprayer design and geometry. We applied low-flow DESI to image porcine liver and rat brain tissue sections at a spatial resolution of 5-10 μm, and the resulting ion images showed high spatial fidelity and detailed tissue histologic features. Building on the nondestructive nature of DESI-MS, we demonstrate that a tissue section can be first imaged with low-flow DESI at lower resolution (100-200 μm pixel size), followed by high-resolution (5-10 μm pixel size) imaging of selected regions of interest in the same tissue section. Lastly, we applied low-flow DESI to image and classify human thyroid cancer tissue sections and fine-needle aspiration (FNA) biopsies at 10 μm spatial resolution, achieving accurate identification of cancer cells in the FNA sample. Altogether, these results demonstrate the robustness and applicability of low-flow DESI-MS for high spatial resolution imaging of tissue sections, which could in the future potentially be implemented across a variety of biomedical and clinical studies.

Authors

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2025-12-04
DOI
https://doi.org/10.1021/jasms.5c00279
Citations
4
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
3.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of Low-Flow High-Resolution Desorption Electrospray Ionization Mass Spectrometry Imaging

Jack Ballantyne, Emrys A. Jones, Lívia S. Eberlin, Mark Towers et al.
4 citations
Journal of the American Society for Mass Spectrometry
Mass Spectrometry Techniques and Applications
3.03
article

Development of Low-Flow High-Resolution Desorption Electrospray Ionization Mass Spectrometry Imaging

Jack Ballantyne, Emrys A. Jones, Lívia S. Eberlin, Mark Towers, James Suliburk, Rachel J. DeHoog, Trevor M. Godfrey, Lisa A Towers
article en
4 citations

Abstract

Desorption electrospray ionization mass spectrometry (DESI-MS) imaging is a well-established technique for molecular analysis of biological samples, although its spatial resolution has been limited when compared to other MS imaging techniques. Here, we describe the development and optimization of a low-flow DESI-MS method that allows for sub-10 μm spatial resolution tissue imaging using a commercial DESI sprayer. Key technical modifications that enabled low-flow high-resolution DESI-MS imaging include reduced solvent flow rates below 350 nL/min, increased solvent pump back-pressure for spray stability, and optimized sprayer design and geometry. We applied low-flow DESI to image porcine liver and rat brain tissue sections at a spatial resolution of 5-10 μm, and the resulting ion images showed high spatial fidelity and detailed tissue histologic features. Building on the nondestructive nature of DESI-MS, we demonstrate that a tissue section can be first imaged with low-flow DESI at lower resolution (100-200 μm pixel size), followed by high-resolution (5-10 μm pixel size) imaging of selected regions of interest in the same tissue section. Lastly, we applied low-flow DESI to image and classify human thyroid cancer tissue sections and fine-needle aspiration (FNA) biopsies at 10 μm spatial resolution, achieving accurate identification of cancer cells in the FNA sample. Altogether, these results demonstrate the robustness and applicability of low-flow DESI-MS for high spatial resolution imaging of tissue sections, which could in the future potentially be implemented across a variety of biomedical and clinical studies.

Journal of the American Society for Mass SpectrometryVol. 37(1)
Waters (United States) (US), Baylor College of Medicine (US)
Openalex Percentile: Top 8%
Mass Spectrometry Techniques and Applications
3.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.