Accuracy of polyvinyl siloxane ether and other impression materials in full-arch implant rehabilitation with varying angulations: A comparative <i>in vitro</i> study

This study evaluated the accuracy of digital and conventional impressions using different materials in fully edentulous jaws with implants at varying angulations. Two master models were fabricated: one with four parallel and another with four implants placed according to the all-on-4 protocol. Impressions were obtained using three materials-polyvinyl siloxane (PVS), polyether (PE), and polyvinyl siloxane ether (PVSE)-and a digital scanner (TRIOS 4). Conventional impressions were cast, scanned with an extraoral scanner, and compared with the reference models via Geomagic Control X software. In the parallel model, digital impressions exhibited significantly greater deviation values than PE (p=0.016). In the angulated model, PE demonstrated significantly lower deviation values compared to PVSE (p=0.007) and digital impressions (p=0.016). Deviation values increased with implant angulation in all groups, except PVSE, which showed no statistically significant difference. Polyether provided the highest accuracy. Implant angulation adversely affected accuracy across most impression methods.

Authors

Institutions

Publication Details

Journal
Dental Materials Journal
Published
2025-12-03
DOI
https://doi.org/10.4012/dmj.2025-150
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of polyvinyl siloxane ether and other impression materials in full-arch implant rehabilitation with varying angulations: A comparative in vitro study

Ender Kazazoğlu, Zeynep Özkurt‐Kayahan, Akanay Çopuroğlu
Dental Materials Journal
Dental Implant Techniques and Outcomes
article

Accuracy of polyvinyl siloxane ether and other impression materials in full-arch implant rehabilitation with varying angulations: A comparative in vitro study

Ender Kazazoğlu, Zeynep Özkurt‐Kayahan, Akanay Çopuroğlu
article en

Abstract

This study evaluated the accuracy of digital and conventional impressions using different materials in fully edentulous jaws with implants at varying angulations. Two master models were fabricated: one with four parallel and another with four implants placed according to the all-on-4 protocol. Impressions were obtained using three materials-polyvinyl siloxane (PVS), polyether (PE), and polyvinyl siloxane ether (PVSE)-and a digital scanner (TRIOS 4). Conventional impressions were cast, scanned with an extraoral scanner, and compared with the reference models via Geomagic Control X software. In the parallel model, digital impressions exhibited significantly greater deviation values than PE (p=0.016). In the angulated model, PE demonstrated significantly lower deviation values compared to PVSE (p=0.007) and digital impressions (p=0.016). Deviation values increased with implant angulation in all groups, except PVSE, which showed no statistically significant difference. Polyether provided the highest accuracy. Implant angulation adversely affected accuracy across most impression methods.

Dental Materials JournalVol. 45(1)
Yeditepe University (TR), Galatasaray University (TR)
Openalex Percentile: Top 47%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accuracy of polyvinyl siloxane ether and other impression materials in full-arch implant rehabilitation with varying angulations: A comparative <i>in vitro</i> study — Ender Kazazoğlu, Zeynep Özkurt‐Kayahan, et al. · Dental Materials Journal (2025) | TGRS Research Map | TGRS