How We Treat <scp>PD</scp> Catheter Thinning Around the Exit Site to Prevent Catheter Rupture

Peritoneal catheter thinning is a rare complication that often occurs in patients undergoing peritoneal dialysis, finally leading to catheter rupture. Once it occurs near the proximal portion of the exit site, catheter removal and simultaneous insertion of a new catheter are often required. Here, we report a case of PD catheter rupture due to catheter thinning 6 years ago, and catheter thinning of a new catheter reoccurred 6 years later. In this recurrence, we successfully addressed the issue through tunnel reconstruction without removing the catheter. After cutting the catheter proximally 1 cm away from the thinning site, we connected a new catheter to the original catheter using a bidirectional connector. A new tunnel was re-constructed on the same side with subsequent excellent catheter function. Tunnel reconstruction may be a simple and safe therapeutic alternative for PD patients with worn or ruptured PD catheters.

Authors

Institutions

Publication Details

Journal
Nephrology
Published
2025-12-01
DOI
https://doi.org/10.1111/nep.70155
Primary Topic
Dialysis and Renal Disease Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

How We Treat PD Catheter Thinning Around the Exit Site to Prevent Catheter Rupture

Minglie Hu, Longkai Li, Bengt Lindholm, Feifei Zhao et al.
Nephrology
Dialysis and Renal Disease Management
article

How We Treat PD Catheter Thinning Around the Exit Site to Prevent Catheter Rupture

Minglie Hu, Longkai Li, Bengt Lindholm, Feifei Zhao, Yueqi Wang, Jing Tian, Hongli Lin, Dan Zhou, Z. Li
article en

Abstract

Peritoneal catheter thinning is a rare complication that often occurs in patients undergoing peritoneal dialysis, finally leading to catheter rupture. Once it occurs near the proximal portion of the exit site, catheter removal and simultaneous insertion of a new catheter are often required. Here, we report a case of PD catheter rupture due to catheter thinning 6 years ago, and catheter thinning of a new catheter reoccurred 6 years later. In this recurrence, we successfully addressed the issue through tunnel reconstruction without removing the catheter. After cutting the catheter proximally 1 cm away from the thinning site, we connected a new catheter to the original catheter using a bidirectional connector. A new tunnel was re-constructed on the same side with subsequent excellent catheter function. Tunnel reconstruction may be a simple and safe therapeutic alternative for PD patients with worn or ruptured PD catheters.

NephrologyVol. 30(12)
Karolinska University Hospital (SE), Dalian Medical University (CN), Karolinska Institutet (SE), First Affiliated Hospital of Dalian Medical University (CN), Baxter (Sweden) (SE), China Medical University (CN)
Openalex Percentile: Top 52%
Dialysis and Renal Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

How We Treat <scp>PD</scp> Catheter Thinning Around the Exit Site to Prevent Catheter Rupture — Minglie Hu, Longkai Li, et al. · Nephrology (2025) | TGRS Research Map | TGRS