Biomechanical Analysis of Newly Developed Local Hip Implant from Stainless Steel, Cobalt-Chrome, and Titanium Materials Using the Finite Element Method

Background: Total hip arthroplasty (THA) is one of the most successful health interventions in the last century.However, there have been several reports of dissatisfaction with the hip implant.Most modern implants are manufactured based on Western morphology.This generalized design may not be suitable for all races, particularly Asians, who tend to have a more petite physique and distinct femoral anatomy. Methods and Results:This study evaluated the biomechanical properties of a newly developed local hip implant using the Finite Element method based on ISO 7206-4, ISO 7206-6, and ASTM F2996-20.The implants were analyzed under static and dynamic load, and three different implant materials were used.The results showed that the titanium (Ti6Al4V) implant had the lowest von Mises stress, the cobalt-chrome (Co28Cr6Mo) implant had the lowest total deformation, and the stainless steel (SS316L) implant had the highest alternating stress and a lower life cycle.All of the materials have more than 1 (>1) safety factor value, which is considered safe for implant manufacturing. Conclusion:This study offers insights into the performance of various materials under static and dynamic loading conditions, demonstrating that all simulated materials are deemed safe for implant manufacturing.

Institutions

Publication Details

Journal
International Journal of Biomedicine
Published
2025-12-05
DOI
https://doi.org/10.21103/article15(4)_oa9
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical Analysis of Newly Developed Local Hip Implant from Stainless Steel, Cobalt-Chrome, and Titanium Materials Using the Finite Element Method

International Journal of Biomedicine
Orthopaedic implants and arthroplasty
article

Biomechanical Analysis of Newly Developed Local Hip Implant from Stainless Steel, Cobalt-Chrome, and Titanium Materials Using the Finite Element Method

article en

Abstract

Background: Total hip arthroplasty (THA) is one of the most successful health interventions in the last century.However, there have been several reports of dissatisfaction with the hip implant.Most modern implants are manufactured based on Western morphology.This generalized design may not be suitable for all races, particularly Asians, who tend to have a more petite physique and distinct femoral anatomy. Methods and Results:This study evaluated the biomechanical properties of a newly developed local hip implant using the Finite Element method based on ISO 7206-4, ISO 7206-6, and ASTM F2996-20.The implants were analyzed under static and dynamic load, and three different implant materials were used.The results showed that the titanium (Ti6Al4V) implant had the lowest von Mises stress, the cobalt-chrome (Co28Cr6Mo) implant had the lowest total deformation, and the stainless steel (SS316L) implant had the highest alternating stress and a lower life cycle.All of the materials have more than 1 (>1) safety factor value, which is considered safe for implant manufacturing. Conclusion:This study offers insights into the performance of various materials under static and dynamic loading conditions, demonstrating that all simulated materials are deemed safe for implant manufacturing.

International Journal of BiomedicineVol. 15(4)
Sepuluh Nopember Institute of Technology (ID), Universitas Airlangga (ID)
Lembaga Pengelola Dana Pendidikan
Openalex Percentile: Top 42%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Biomechanical Analysis of Newly Developed Local Hip Implant from Stainless Steel, Cobalt-Chrome, and Titanium Materials Using the Finite Element Method · International Journal of Biomedicine (2025) | TGRS Research Map | TGRS