Investigation of Sample Preparation Methods of Dietary Supplements for Total Selenium Determination

This study investigated three sample preparation methods for digestion of dietary supplements prior to selenium (Se) determination by graphite furnace atomic absorption spectrometry (GF AAS), such as conductive heating digestion, microwave-assisted wet digestion (MWAD), and microwave-induced combustion (MIC). In wet digestion methods, variable nitric acid and hydrogen peroxide concentrations were evaluated. For MIC, a diluted nitric acid concentration was also investigated as absorbing solution, while microcrystalline cellulose was employed as a combustion aid. The optimized conditions were: 250 mg of the sample with 5 mol L<sup>-1</sup> nitric acid and 30% w/w hydrogen peroxide (160 °C, 5 h) for conductive heating; 350 mg with 2.5 mol L<sup>-1</sup> nitric acid and 30% w/w hydrogen peroxide (180 °C, 40 min) for MWAD; and 200 mg of sample, 300 mg of microcrystalline cellulose, and 0.25 mol L<sup>-1</sup> nitric acid as the absorbing solution (29.2 bar, > 1000 °C during the combustion reaction and 180 °C, 20 min in the reflux step) for MIC. Digestion efficiency was evaluated by residual carbon content (RCC) and residual acidity (RA) in final solutions. The greenness of each method was evaluated by using the AGREEprep software. Selenium was quantified by GF AAS using Pd as the chemical modifier using pyrolysis and atomization temperatures of 1200 and 2000 °C, respectively. The limits of detection (LOD) obtained for Se were 1.71, 0.84, and 0.08 μg g<sup>-1</sup> for conductive heating, MWAD, and MIC, respectively, with agreement of 96.7-99.5% for the selenium-enriched yeast certified reference material. Although all methods showed good agreement (ANOVA, 95% confidence level), MIC was the most efficient, providing the lowest RCC (0.1%) and RA (0.5%) values, better LOD, and a greenness score of 0.49.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2025-12-04
DOI
https://doi.org/10.1021/acsomega.5c08938
Citations
1
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.75
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of Sample Preparation Methods of Dietary Supplements for Total Selenium Determination

Larissa M.A. de Oliveira, Juliana S.F. Pereira, Diogo P. Moraes
1 citations
ACS Omega
Analytical chemistry methods development
0.75
article

Investigation of Sample Preparation Methods of Dietary Supplements for Total Selenium Determination

Larissa M.A. de Oliveira, Juliana S.F. Pereira, Diogo P. Moraes
article en
1 citations

Abstract

This study investigated three sample preparation methods for digestion of dietary supplements prior to selenium (Se) determination by graphite furnace atomic absorption spectrometry (GF AAS), such as conductive heating digestion, microwave-assisted wet digestion (MWAD), and microwave-induced combustion (MIC). In wet digestion methods, variable nitric acid and hydrogen peroxide concentrations were evaluated. For MIC, a diluted nitric acid concentration was also investigated as absorbing solution, while microcrystalline cellulose was employed as a combustion aid. The optimized conditions were: 250 mg of the sample with 5 mol L<sup>-1</sup> nitric acid and 30% w/w hydrogen peroxide (160 °C, 5 h) for conductive heating; 350 mg with 2.5 mol L<sup>-1</sup> nitric acid and 30% w/w hydrogen peroxide (180 °C, 40 min) for MWAD; and 200 mg of sample, 300 mg of microcrystalline cellulose, and 0.25 mol L<sup>-1</sup> nitric acid as the absorbing solution (29.2 bar, > 1000 °C during the combustion reaction and 180 °C, 20 min in the reflux step) for MIC. Digestion efficiency was evaluated by residual carbon content (RCC) and residual acidity (RA) in final solutions. The greenness of each method was evaluated by using the AGREEprep software. Selenium was quantified by GF AAS using Pd as the chemical modifier using pyrolysis and atomization temperatures of 1200 and 2000 °C, respectively. The limits of detection (LOD) obtained for Se were 1.71, 0.84, and 0.08 μg g<sup>-1</sup> for conductive heating, MWAD, and MIC, respectively, with agreement of 96.7-99.5% for the selenium-enriched yeast certified reference material. Although all methods showed good agreement (ANOVA, 95% confidence level), MIC was the most efficient, providing the lowest RCC (0.1%) and RA (0.5%) values, better LOD, and a greenness score of 0.49.

ACS OmegaVol. 10(49)
Universidade Federal do Rio Grande do Sul (BR)
Openalex Percentile: Top 24%
Analytical chemistry methods development
0.75
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.