Effects of subject motion and acquisition time on cone‐beam CT‐guided adaptive therapy for novel 6 second fast scanning protocols

CB-16.6 and CB-6 provided high-quality images for ART. Compared to FB-0.5, fast CBCT exhibited increased blurring and streaking but significantly less geometric distortion with increasing motion, leading to reduced dose delivery error in a simulated ART workflow. The complex 3D motion phantom study supported trends observed in the 1D translational phantom study. Faster CBCT (6 vs. 16.6 s) reduced blur, improving auto-contouring performance for both periodic and non-periodic motions, but the interplay between the motion period and 6 s image acquisition must be carefully managed.

Authors

Institutions

Publication Details

Journal
Medical Physics
Published
2025-12-01
DOI
https://doi.org/10.1002/mp.70181
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of subject motion and acquisition time on cone‐beam CT‐guided adaptive therapy for novel 6 second fast scanning protocols

Boon‐Keng Teo, William T. Hrinivich, Alejandro Sisniega, Michael Salerno et al.
Medical Physics
Advanced Radiotherapy Techniques
article

Effects of subject motion and acquisition time on cone‐beam CT‐guided adaptive therapy for novel 6 second fast scanning protocols

Boon‐Keng Teo, William T. Hrinivich, Alejandro Sisniega, Michael Salerno, Xun Jia, Alexander Lu, Jeffrey H. Siewerdsen, David P. Adam, Taoran Li
article en

Abstract

CB-16.6 and CB-6 provided high-quality images for ART. Compared to FB-0.5, fast CBCT exhibited increased blurring and streaking but significantly less geometric distortion with increasing motion, leading to reduced dose delivery error in a simulated ART workflow. The complex 3D motion phantom study supported trends observed in the 1D translational phantom study. Faster CBCT (6 vs. 16.6 s) reduced blur, improving auto-contouring performance for both periodic and non-periodic motions, but the interplay between the motion period and 6 s image acquisition must be carefully managed.

Medical PhysicsVol. 52(12)
The University of Texas MD Anderson Cancer Center (US), Johns Hopkins University (US), Varian Medical Systems (United States) (US), University of Pennsylvania (US)
Openalex Percentile: Top 53%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.