Automation and performance validation of the pooled donor basophil activation test for chronic urticaria using the Hamilton STAR system

This study presents the automation of the pooled donor basophil activation test (PD-BAT) for chronic urticaria, transitioning from a previously published manual assay in tubes to an automated 96-well plate format using the Hamilton Microlab STAR system. The primary aim is to enhance throughput and robustness in a commercial lab environment while maintaining assay accuracy and reproducibility. Donor screening included 36 individuals, of which 16 were selected for pooled assays. A total of 90 sera were analyzed in parallel by manual and automated methods. The automated PD-BAT demonstrated 93.3% qualitative agreement (r > 0.97) with the manual assay. Throughput improved through automation, a 66% reduction in hands-on time was observed between the manual (9 h/batch) and automated (3 h/batch) methods. Discordant results (6.7%) occurred only near the technical cutoff, highlighting both the robustness and limitations of the method. This automation represents a valuable advancement over the manual assay, optimizing laboratory workflows.

Authors

Institutions

Publication Details

Journal
Journal of Immunological Methods
Published
2025-12-05
DOI
https://doi.org/10.1016/j.jim.2025.114009
Primary Topic
Urticaria and Related Conditions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automation and performance validation of the pooled donor basophil activation test for chronic urticaria using the Hamilton STAR system

Saintedym Wills, Russell P. Grant, Deborah Boles, Jessica Chavez et al.
Journal of Immunological Methods
Urticaria and Related Conditions
article

Automation and performance validation of the pooled donor basophil activation test for chronic urticaria using the Hamilton STAR system

Saintedym Wills, Russell P. Grant, Deborah Boles, Jessica Chavez, E A McConnell, André Valcour, Christopher M. Shuford, Ajay Grover, Rogger Alcalde
article en

Abstract

This study presents the automation of the pooled donor basophil activation test (PD-BAT) for chronic urticaria, transitioning from a previously published manual assay in tubes to an automated 96-well plate format using the Hamilton Microlab STAR system. The primary aim is to enhance throughput and robustness in a commercial lab environment while maintaining assay accuracy and reproducibility. Donor screening included 36 individuals, of which 16 were selected for pooled assays. A total of 90 sera were analyzed in parallel by manual and automated methods. The automated PD-BAT demonstrated 93.3% qualitative agreement (r > 0.97) with the manual assay. Throughput improved through automation, a 66% reduction in hands-on time was observed between the manual (9 h/batch) and automated (3 h/batch) methods. Discordant results (6.7%) occurred only near the technical cutoff, highlighting both the robustness and limitations of the method. This automation represents a valuable advancement over the manual assay, optimizing laboratory workflows.

Journal of Immunological MethodsVol. 546
LabCorp (United States) (US)
Openalex Percentile: Top 45%
Urticaria and Related Conditions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Automation and performance validation of the pooled donor basophil activation test for chronic urticaria using the Hamilton STAR system — Saintedym Wills, Russell P. Grant, et al. · Journal of Immunological Methods (2025) | TGRS Research Map | TGRS