Size-dependent plasma–nanoparticle interactions in Laser Induced Breakdown Spectroscopy

The detection of nanoparticles (NPs) by Laser-Induced Breakdown Spectroscopy (LIBS) is gaining increasing interest in the analytical chemistry community, both for the elemental analysis of the NPs themselves and in view of their use as tags in biomedical applications. In the present work, the origin and characteristics of the atomic emission signal produced by NP vaporization during LIBS were investigated both experimentally and theoretically, focusing on the effect of NP size (ranging from 5 to 100 nm) on the sensitivity of calibration curves. To this end, we determined the dependence of the calibration curve slope on the NP size, so to assess the effect of NP dimensions on the production of emitters and consequently on the emission analytical signal. LIBS was tested on AuNPs and AgNPs deposited on different substrates: nitrocellulose paper, silicon and copper. It was observed that, although smaller NPs vaporize more efficiently according to the Gibbs-Thomson theory, the larger surface area of bigger NPs results in a higher evaporation yield in terms of the total number of atoms. Consequently, larger NPs generate more emitters and lead to lower limits of detection.

Authors

Institutions

Publication Details

Journal
Talanta
Published
2025-12-05
DOI
https://doi.org/10.1016/j.talanta.2025.129216
Primary Topic
Laser-induced spectroscopy and plasma
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Size-dependent plasma–nanoparticle interactions in Laser Induced Breakdown Spectroscopy

R. Gaudiuso, M. Dell’Aglio, Aya Taleb, Alessandro De Giacomo
Talanta
Laser-induced spectroscopy and plasma
article

Size-dependent plasma–nanoparticle interactions in Laser Induced Breakdown Spectroscopy

R. Gaudiuso, M. Dell’Aglio, Aya Taleb, Alessandro De Giacomo
article en

Abstract

The detection of nanoparticles (NPs) by Laser-Induced Breakdown Spectroscopy (LIBS) is gaining increasing interest in the analytical chemistry community, both for the elemental analysis of the NPs themselves and in view of their use as tags in biomedical applications. In the present work, the origin and characteristics of the atomic emission signal produced by NP vaporization during LIBS were investigated both experimentally and theoretically, focusing on the effect of NP size (ranging from 5 to 100 nm) on the sensitivity of calibration curves. To this end, we determined the dependence of the calibration curve slope on the NP size, so to assess the effect of NP dimensions on the production of emitters and consequently on the emission analytical signal. LIBS was tested on AuNPs and AgNPs deposited on different substrates: nitrocellulose paper, silicon and copper. It was observed that, although smaller NPs vaporize more efficiently according to the Gibbs-Thomson theory, the larger surface area of bigger NPs results in a higher evaporation yield in terms of the total number of atoms. Consequently, larger NPs generate more emitters and lead to lower limits of detection.

TalantaVol. 300
Center for Biomolecular Nanotechnologies (IT), University of Bari Aldo Moro (IT)
Openalex Percentile: Top 57%
Laser-induced spectroscopy and plasma
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Size-dependent plasma–nanoparticle interactions in Laser Induced Breakdown Spectroscopy — R. Gaudiuso, M. Dell’Aglio, et al. · Talanta (2025) | TGRS Research Map | TGRS